Wearable sensors have recently been used to evaluate biomechanical parameters of everyday movements, but few have been located at the head level. This study investigated the relative and absolute reliability (intra- and inter-session) and concurrent validity of an inertial measurement unit (IMU) embedded in smart eyeglasses during sit-to-stand (STS) movements for the measurement of maximal acceleration of the head. Reliability and concurrent validity were investigated in nineteen young and healthy participants by comparing the acceleration values of the glasses’ IMU to an optoelectronic system. Sit-to-stand movements were performed in laboratory conditions using standardized tests. Participants wore the smart glasses and completed two testing sessions with STS movements performed at two speeds (slow and comfortable) under two different conditions (with and without a cervical collar). Both the vertical and anteroposterior acceleration values were collected and analyzed. The use of the cervical collar did not significantly influence the results obtained. The relative reliability intra- and inter-session was good to excellent (i.e., intraclass correlation coefficients were between 0.78 and 0.91) and excellent absolute reliability (i.e., standard error of the measurement lower than 10% of the average test or retest value) was observed for the glasses, especially for the vertical axis. Whatever the testing sessions in all conditions, significant correlations (p < 0.001) were found for the acceleration values recorded either in the vertical axis and in the anteroposterior axis between the glasses and the optoelectronic system. Concurrent validity between the glasses and the optoelectronic system was observed. Our observations indicate that the IMU embedded in smart glasses is accurate to measure vertical acceleration during STS movements. Further studies should investigate the use of these smart glasses to assess the STS movement in unstandardized settings (i.e., clinical and/or home) and to report vertical acceleration values in an elderly population of fallers and non-fallers.
The study aims to determine the validity and reproducibility of step duration and step length parameters measured during walking in healthy participants using an accelerometer embedded in smart eyeglasses. Twenty young volunteers participated in two identical sessions comprising a 30 s gait assessment performed at three different treadmill speeds under two conditions (i.e., with and without a cervical collar). Spatiotemporal parameters (i.e., step duration and step length normalized by the lower limb length) were obtained with both the accelerometer embedded in smart eyeglasses and an optoelectronic system. The relative intra- and inter-session reliability of step duration and step length computed from the vertical acceleration data were excellent for all experimental conditions. An excellent absolute reliability was observed for the eyeglasses for all conditions and concurrent validity between systems was observed. An accelerometer incorporated in smart eyeglasses is accurate to measure step duration and step length during gait.
Background As people age, their physical capacities (eg, walking and balance) decline and the risk of falling rises. Yet, classic fall detection devices are poorly accepted by older adults. Because they often wear eyeglasses as they go about their daily activities, daily monitoring to detect and prevent falls with smart eyeglasses might be more easily accepted. Objective On the basis of the Unified Theory of Acceptance and Use of Technology 2 (UTAUT2), this study evaluated (1) the acceptability of smart eyeglasses for the detection and prevention of falls by older adults and (2) the associations with selected fall-related functional physical capacities. Methods A total of 142 volunteer older adults (mean age 74.9 years, SD 6.5 years) completed the UTAUT2 questionnaire adapted for smart eyeglasses and then performed several physical tests: a unipodal balance test with eyes open and closed, a 10-m walk test, and a 6-minute walk test. An unsupervised analysis classified the participants into physical performance groups. Multivariate ANOVAs were performed to identify differences in acceptability constructs according to the performance group. Results The UTAUT2 questionnaire adapted for eyeglasses presented good psychometric properties. Performance expectancy (β=.21, P=.005), social influence (β=.18, P=.007), facilitating conditions (β=.17, P=.04), and habit (β=.40, P<.001) were significant contributors to the behavioral intention to use smart eyeglasses (R²=0.73). The unsupervised analysis based on fall-related functional physical capacities created 3 groups of physical performance: low, intermediate, and high. Effort expectancy in the low performance group (mean 3.99, SD 1.46) was lower than that in the other 2 groups (ie, intermediate: mean 4.68, SD 1.23; high: mean 5.09, SD 1.41). Facilitating conditions in the high performance group (mean 5.39, SD 1.39) were higher than those in the other 2 groups (ie, low: mean 4.31, SD 1.68; intermediate: mean 4.66, SD 1.51). Conclusions To our knowledge, this study is the first to examine the acceptability of smart eyeglasses in the context of fall detection and prevention in older adults and to associate acceptability with fall-related functional physical capacities. The older adults with higher physical performances, and possibly lower risks of falling, reported greater acceptability of smart eyeglasses for fall prevention and detection than their counterparts exhibiting low physical performances.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.