Background Mechanical ventilation is often employed to facilitate breathing in patients suffering from respiratory illnesses and disabilities. Despite the benefits, there are risks associated with ventilator-induced lung injuries and death, driving investigations for alternative ventilation techniques to improve mechanical ventilation, such as multi-oscillatory and high-frequency ventilation; however, few studies have evaluated fundamental lung mechanical local deformations under variable loading. Methods Porcine whole lung samples were analyzed using a novel application of digital image correlation interfaced with an electromechanical ventilation system to associate the local behavior to the global volume and pressure loading in response to various inflation volumes and breathing rates. Strains, anisotropy, tissue compliance, and the evolutionary response of the inflating lung were analyzed. Results Experiments demonstrated a direct and near one-to-one linear relationship between applied lung volumes and resulting local mean strain, and a nonlinear relationship between lung pressures and strains. As the applied air delivery volume was doubled, the tissue surface mean strains approximately increased from 20 to 40%, and average maximum strains measured 70–110%. The tissue strain anisotropic ratio ranged from 0.81 to 0.86 and decreased with greater inflation volumes. Local tissue compliance during the inflation cycle, associating evolutionary strains in response to inflation pressures, was also quantified. Conclusion Ventilation frequencies were not found to influence the local stretch response. Strain measures significantly increased and the anisotropic ratio decreased between the smallest and greatest tidal volumes. Tissue compliance did not exhibit a unifying trend. The insights provided by the real-time continuous measures, and the kinetics to kinematics pulmonary linkage established by this study offers valuable characterizations for computational models and establishes a framework for future studies to compare healthy and diseased lung mechanics to further consider alternatives for effective ventilation strategies.
Respiratory pathologies alter the structure of the lung and impact its mechanics. Mice are widely used in the study of lung pathologies, but there is a lack of fundamental mechanical measurements assessing the interdependent effect of varying inflation volumes and cycling frequency. In this study, the mechanical properties of five male C57BL/6J mice (29–33 weeks of age) lungs were evaluated ex vivo using our custom-designed electromechanical, continuous measure ventilation apparatus. We comprehensively quantify and analyze the effect of loading volumes (0.3, 0.5, 0.7, 0.9 ml) and breathing rates (5, 10, 20 breaths per minute) on pulmonary inflation and deflation mechanical properties. We report means of static compliance between 5.4–16.1 µl/cmH2O, deflation compliance of 5.3–22.2 µl/cmH2O, percent relaxation of 21.7–39.1%, hysteresis of 1.11–7.6 ml•cmH2O, and energy loss of 39–58% for the range of four volumes and three rates tested, along with additional measures. We conclude that inflation volume was found to significantly affect hysteresis, static compliance, starting compliance, top compliance, deflation compliance, and percent relaxation, and cycling rate was found to affect only hysteresis, energy loss, percent relaxation, static compliance and deflation compliance.
This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Tissue remodeling in pulmonary disease irreversibly alters lung functionality and impacts quality of life. Mechanical ventilation is amongst the few pulmonary interventions to aid respiration, but can be harmful or fatal, inducing excessive regional (i.e., local) lung strains. Previous studies have advanced understanding of diseased global-level lung response under ventilation, but do not adequately capture the critical local-level response. Here, we pair a custom-designed pressure–volume ventilator with new applications of digital image correlation, to directly assess regional strains in the fibrosis-induced ex-vivo mouse lung, analyzed via regions of interest. We discuss differences between diseased and healthy lung mechanics, such as distensibility, heterogeneity, anisotropy, alveolar recruitment, and rate dependencies. Notably, we compare local and global compliance between diseased and healthy states by assessing the evolution of pressure-strain and pressure–volume curves resulting from various ventilation volumes and rates. We find fibrotic lungs are less-distensible, with altered recruitment behaviors and regional strains, and exhibit disparate behaviors between local and global compliance. Moreover, these diseased characteristics show volume-dependence and rate trends. Ultimately, we demonstrate how fibrotic lungs may be particularly susceptible to damage when contrasted to the strain patterns of healthy counterparts, helping to advance understanding of how ventilator induced lung injury develops.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.