We present and analyze characteristics of the runaway electron flow in a high-voltage (the voltage rise rate of up to 1.5 MV/ns) air-filled electrode gap with a strongly nonuniform electric field. It is demonstrated that such a flow contains a high-energy electron component of duration not more than 10 ps. According to numerical simulations, runaway electron generation/termination is governed by impact ionization of the gas near the cathode and switching on/off a critical (sufficient for electrons to run away) electric field at the boundary of the expanding cathode plasma. The corresponding characteristic time estimated to be 2–3 ps is defined by the ionization rate at a critical field.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.