The Pre-Series Cryoline (PTCL) for ITER is a representative cryoline from the complicated network of all cryolines for the ITER project. It is ~28 m in length with same cross-section (1:1) including main line (ML) and branch line (BL) as of ITER torus & cryostat cryoline. Geometrically; it has bends at different angles i.e. 90°, 120°, 135° & 160° comprising T-section & Z-section. The PTCL has been fabricated in 5 different elements based on the installation feasibility. The mechanical & instrumentation installation like sensors mounting, displacement sensors, etc. has been completed. The PTCL test has been performed after complete installation of PTCL and integration with the existing test facility at ITER-India cryogenics laboratory in order to verify the thermal performance and mechanical integrity. The primary objectives, which are evaluated during the PTCL test, are (i) Thermal performance of the PTCL (ii) Measurement of temperature profile on thermal shield of PTCL, (iii) Stress measurement at critical locations, (iv) Measurement of Outer Vacuum Jacket (OVJ) temperature during Break of Insulation Vacuum (BIV) test. The paper will summarize the methodology and observed results of PTCL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.