The fixation of fractured bone with screws is important for orthopedic surgery, however, rigid fixation often cannot be attained in elderly patients with osteoporosis. Recently, we developed a new injectable, nonresorbable bone cement (CAP) that possesses mechanical and biological properties superior to those of polymethylmethacrylate (PMMA) cement. CAP can directly bond with bone without intervening fibrous tissue, and the peak curing temperature is 46 degrees C. In this study, we assessed the effects of CAP and PMMA cement on the augmentation of screw fixation in vivo. A cancellous screw was placed in the proximal metaphysis of rabbit tibiae. One side of each tibia was randomly selected to be augmented with CAP or PMMA. The contralateral side received a screw without cement (control). Of the 36 rabbits included in this study, 9 rabbits from each group were sacrificed and the tibial constructs retrieved 1 or 3 months after the initial operation. The screws were then pulled out to failure. The values of the pullout force of the screws augmented with CAP and PMMA were higher than those of the control specimens at both 1 month (319 +/- 58 N for CAP vs. 105 +/- 41 N for control; p < 0.05, 284 +/- 100 N for PMMA vs. 132 +/- 71 N for control; p < 0.05) and 3 months (387 +/- 109 N for CAP vs. 196 +/- 107 N for control; p < 0.05, 372 +/- 145 N for PMMA vs. 242 +/- 100 N for control; p > 0.05) after the operation. However, the average increase in the pullout force between CAP and PMMA augmentation was not statistically significant at either time. The values of energy absorption augmented with CAP and PMMA were also higher than those of the control specimens at both 1 month (129 +/- 54 N*mm for CAP vs. 19 +/- 10 N*mm for control; p < 0.05, 145 +/- 95 N*mm for PMMA vs. 28 +/- 21 N*mm for control; p < 0.05) and 3 months (172 +/- 58 N*mm for CAP vs. 44 +/- 41N*mm for control; p < 0.05, 185 +/- 198 N*mm for PMMA vs. 67 +/- 49N*mm for control; p > 0.05) after the operation. However, there were also no significant differences in energy absorption between the two types of cement augmentation. On the other hand, a significant increase was not observed in stiffness among the CAP, PMMA, and respective control groups at either 1 month (626 +/- 133 N/mm for CAP vs. 441 +/- 180 N/mm for control; p < 0.05, 577 +/- 87 N/mm for PMMA vs. 450 +/- 121 N/mm for control; p > 0.05) or 3 months (622 +/- 144 N/mm for CAP vs. 600 +/- 204 N/mm for control; p > 0.05, 633 +/- 175 N/mm for PMMA vs. 630 +/- 168 N/mm for control; p > 0.05) after the operation, except in the average increase between CAP augmentation and its control 1 month after the operation. These results suggested that a cancellous screw fixation augmented with CAP, as well as PMMA, was effective compared with the unaugmented control in vivo. Because of its biocompatibility and low curing temperature, CAP can be used clinically to augment cancellous screw fixation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.