BackgroundImaging modalities are essential for the diagnosis of ankylosing spondylitis (AS). Radiographic sacroiliitis is the requirement of 1984 modified New York (mNY) criteria for AS but with the disadvantage of low sensitivity. MRI has the advantage of detecting active inflammatory lesions but was criticized for low specificity. Computerized tomography (CT) has higher diagnostic accuracy than radiography in detecting structural changes, but its application has been limited for high radiation dose. The reduction of radiation dose can be achieved by decreasing the tube current[1] and previous study has demonstrated that effective dose (ED) of semi-coronal sacroiliac joint (SIJ) CT is at least six times lower in female or nearly four times lower in male than that of axial SIJ CT[2].ObjectivesTo evaluate the value of low-dose semi-coronal SIJ CT in the early diagnosis of AS.MethodsThirty-three patients diagnosed by mNY criteria who had pre-existing axial SIJ CT in past two years with visible structural damage were enrolled. These patients underwent low-dose semi-coronal SIJ CT examination which was obtained at 3-mm slices, 140 kV and 120 mAs, with the gantry tilted 20–25° cranially. The ED of the low-dose semi-coronal CT and the pre-existing conventional axial CT were compared. Image qualities of the low-dose semi-coronal CT were blind-graded separately by 2 rheumatologists into poor, fair, good or excellent. And the correlation between image quality and body mass index (BMI) was analyzed. The CT scans were read in a blinded manner by 2 rheumatologists who had been trained by radiologists. CT scans of the two groups were graded respectively by mNY criteria, the criteria established by Lee[3] and the Innsbruck criteria[4]. The kappa coefficient was used to assess the consistency of grading between the two groups.ResultsThirty-three patients received low-dose semi-coronal CT examination with an average ED of 3.37 mSv, which meant a 49% reduction in radiation compared to the pre-existing CT. The quality of images of male patients with BMI<25 kg/m2 and all female patients were good or excellent. Image qualities were assessed as poor or fair in 58% (7/12) male patients whose BMI>25 kg/m2. There was a significant negative correlation between image quality and BMI (r=-0.784,P=0.000). The grading of low-dose semi-coronal CT showed no differences as compared with the pre-existing CT by mNY criteria (see below). For the other two classification criteria, the consistency of grading between the two groups were satisfactory (kappa=0.897 by Lee criteria; kappa=0.814 by Innsbruck criteria; P>0.05).ConclusionsThe radiation dose of low-dose semi-coronal SIJ CT was reduced significantly compared with the conventional axial SIJ CT with acceptable diagnostic efficacy.ReferencesGurung J, et al. Multislice CT of the pelvis: dose reduction with regard to image quality using 16-row CT. Eur Radiol. 2005;15:1898–905.Jurik AG, et al. Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conven...
For the exposure of patients in diagnostic radiology, individual dose limit does not apply, but optimization of radiological protection may play a major role. This project has been carried out with the purpose of improving the protection of patients in medical diagnostic radiology in China utilizing the principles of optimization. Taking Sichuan, Shandong and Beijing as surveyed areas, we investigated the present situation of the protection of patients. In the survey, the patient doses were classified into practical dose, justified dose and optimized dose to evaluate the influences of managerial and equipment factors separately.The results show that there are some urgent protection problems in X-ray protection to be solved in the surveyed regions. This paper, however, points out that the prospects of reducing patient doses are encouraging provided that appropriate measures are adopted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.