In this paper, an analysis of the induction motor control scheme based on the Direct Rotor Flux Oriented Control (DRFOC) for a whole speed range, including field-weakening (FW) regions is presented. Two field-weakening algorithms have been compared and verified through simulation with a 3.0 [kW] induction motor drive.
Abstract. In this paper, an analysis of the influence of the stator winding resistance on the field-weakening operation of the induction motor drive based on the Direct Rotor Flux Oriented Control (DRFOC) is presented. Two scenarions of the optimal field-weakening algorithm (with and without stator winding resistance taken into account) have been compared and verified through simulation and experiment, under different operation conditions of the DRFOC drive system with 3 [kW] induction motor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.