Five hole probes are extensively used for measurement of total and static pressures, flow angles, velocity and its components in turbomachinery, and other aerodynamic flows. Their operating range is usually limited to 30-40 ∘ depending on the type of the probe head. The chamfer angle of the probe is usually taken around 45∘ . Recent studies on three hole probes have shown that 30 ∘ chamfer angle is desirable for unsteady flow measurements. Hence the present investigation is undertaken to find the optimum chamfer angle of five-hole probes. A special five-hole probe of 9.6 mm head diameter and 3 mm diameter pressure take off tubes was designed and fabricated. The large size of the probe was chosen to minimize machining inaccuracies. The probe chamfer angle was varied from 30 ∘ to 60 ∘ in 5 ∘ steps. For each of the chamfer angles, the probe was calibrated in the range of −30 ∘ to +30 ∘ in 5 ∘ interval and the calibration curves are presented. In addition the sensitivities of the calibration coefficients are determined. It is concluded that five-hole probe with a chamfer angle 30 ∘ has large operating range, while five-hole probe with a chamfer angle of 50 ∘ has good sensitivity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.