Normal-incidence ultrasonic scans have been conducted on two-and three-layer adhesive-joint specimens exposed to water at 50 o C for periods of up to 18 months. The joints consisted of aluminium-alloy adherends which were subjected to one of four different surface pretreatments prior to being coated (for the two-layer specimens) or bonded (for the three-layer specimens) with an epoxy polymer. The four commonly used pretreatments which were investigated were a grit-blast, a chromic-acid etch (CAE), a chromic-acid anodise (CAA) and a phosphoric-acid anodise (PAA). Techniques have been developed to measure the fracture toughness, G c , of the specimens before and after water exposure such that fracture toughness maps could be ascertained, where the measured values of G c may be assigned to spatially discrete positions within the specimens. The relative performance of the different pretreatments used in the present work followed that expected from the literature: the chromic-acid anodised (CAA) surface pretreatment giving the most durable two-and three-layer specimens and the grit-blasting pretreatment giving the least durable. In the two-layer specimens, the ultrasonic inspections detected two main types of defects: corrosion-driven edge-disbonds and micro-defects. The edge-disbonding mechanism usually started at an unsealed flush edge, and was initiated by a region of corrosion which developed on the edge of the specimen and which undercut the epoxy layer. Edge-disbonds were easily and accurately detected ultrasonically. Micro-defects were detected in regions remote from the edges and these small-scale, isolated defects took several forms. In the case of the three-layer joint specimens, only edge-disbonds could be detected ultrasonically. Nevertheless, in some of the three-layer joints which were attacked and weakened by ingressing water, the failure surfaces suggested that micro-defects were present. For both the two-and the three-layer specimens, the results from the ultrasonic scans have been correlated with the values of the fracture toughness of the specimens, before and after water exposure. Whilst the ultrasonic scans detected the presence of micro-defects in the two-layer specimens, which appeared to correlate with the extent of interphase toughness loss upon water exposure, the scans clearly failed to detect any changes in the interphase regions which would indicate the general loss of interphase toughness seen with the three-layer grit-blast and PAA specimens.
SummaryNormal-and oblique-incidence ultrasonic scans have been conducted on two-and three-layer adhesive-joint specimens exposed to water at 50 o C for periods of up to 18 months. The joints consisted of aluminium alloy adherend(s) which was subjected to one of four different surface pretreatments prior to being coated (for the two-layer specimens) of bonded (for the three-layer specimens) with an epoxy polymer. Overall, the oblique-incidence technique detected the same types of defect as the normal incidence scans, except when the resolution was too poor to detect the smallest defects. No defect was detected using oblique-incidence scans that could not be detected using normal-incidence scans. In the two-layer specimens, two main types of defects were detected: edge disbonds and micro-defects. Micro-defects were detected in regions remote from the edges and these small-scale, isolated defects appeared took several forms. In the case of the two-layer specimens, the detection of micro-defects was clearly a strong indicator that the interphase of the specimen had been attacked and weakened by the ingressing water molecules and, indeed, the number of such defects correlated to the loss of interfacial toughness. In the case of the three-layer specimens, the extent of edge disbonding was much lower than compared to the corresponding twolayer specimens. Also, no micro-defects were detected ultrasonically in any of the three-layer specimens. However, examination of some of the failure surfaces from the three-layer specimens suggested that some micro-defects may have been present but that they were too small to be detected at the spatial resolution of the ultrasonic scans. Therefore, for the three-layer joint specimens, there were no indicators from the ultrasonic scans which could reveal whether the joint had suffered attack and weakening of the interphase regions by the ingressing moisture. Finally, for all the tests conducted it was very noteworthy that there was no evidence of a gradual change in either the normal-or oblique-incidence reflection coefficient moving into an apparently wellbonded region from either the edge disbonds or the micro-defects, when present.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.