Cultures of the newly isolated bacterial strains AD20, AD25, and AD27, identified as strains ofAncylobacter aquaticus, were capable of growth on 1,2-dichloroethane (DCE) as the sole carbon and energy source. These strains, as well as two other new DCE utilizers, were facultative methylotrophs and were also able to grow on 2-chloroethanol, chloroacetate, and 2-chloropropionate. In all strains tested, DCE was degraded by initial hydrolytic dehalogenation to 2-chloroethanol, followed by oxidation by a phenazine methosulfate-dependent alcohol dehydrogenase and an NAD-dependent aldehyde dehydrogenase. The resulting chloroacetic acid was converted to glycolate by chloroacetate dehalogenase. The alcohol dehydrogenase was induced during growth on methanol or DCE in strain AD20, but no activity was found during growth on glucose. However, in strain AD25 the enzyme was synthesized to a higher level during growth on glucose than on methanol, and it reached levels of around 2 U/mg of protein in late-exponential-phase cultures growing on glucose. The haloalkane dehalogenase was constitutively produced in all strains tested, but strain AD25 synthesized the enzyme at a level of 30 to 40% of the total cellular protein, which is much higher than that found in other DCE degraders. The nucleotide sequences of the haloalkane dehalogenase (dhUA) genes of strains AD20 and AD25 were the same as the sequence of dhL4 from Xanthobacter autotrophicus GJ10 and GJ11. Hybridization experiments showed that the dhlA genes of six different DCE utilizers were all located on an 8.3-kb EcoRI restriction fragment, indicating that the organisms may have obtained the dhlA gene by horizontal gene transmission.
The blood compatibility of ventricular assist devices developed by the Helmholtz Institute Aachen (HA-VAD's) was tested on calves. Seven calves received a non-coated HIA-VAD (control) and three a Bioline heparin coated device. The circulatory support of these HIA-VAD's lasted one week. Mechanical blood cell trauma estimated by hematocrit (Hct), hemoglobin (total Hb) and free plasma hemoglobin (free Hb) levels did not differ in either group. All HIA-VAD's in the control group remained thrombus free, except on one occasion when an inflow cannula was obstructed by a thrombus located in the tip. After circulatory support, the animals in this group seemed clinically healthy. However, thrombus formation was observed in the three heparin coated HIA-VAD's. One animal in this group died from complications after re-operation for pneumothorax on the fifth day of support, whereas the other two animals seemed clinically healthy. In these three animals, a stronge decrease in platelet numbers was measured even after 24 hours of support which recovered after 72 hours. This decrease in platelet numbers was associated with a lower degree of platelet aggregation ability stimulated by ADP (p<0.05). Fibrin(ogen) degradation products (FDP) increased significantly immediately after the implantation procedure (p<0.05). Fibrinogen levels initially decreased during the implantation procedure, but increased thereafter in both groups. The FDP levels remained high in this group, although the FDP levels in both groups were decreased after the implantation procedure. The ex vivo measured circulating heparin levels were lower in the heparin coated HIV-VAD group despite the equally administrated heparin doses in both animal groups. No differences were measured in either group with regard to white blood cell (WBC) numbers and complement hemolytic activity (CH50). Despite these hemostatic changes, no mechanical trauma could be demonstrated after seven days of circulatory support.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.