Since conduction cooling system is environmental friendly and easy operating, the conduction-cooled method is widely used in cryogenic cooling system of high-temperature superconducting (HTS) magnet. The eddy-current losses are generated in the cooling structures when HTS magnet is charging and discharging or the current in the magnet is alternating. In this paper, a 3D model of analyzing the eddy-current loss was built. The eddy-current losses of a HTS magnet with different cooling structures were calculated. Thermal analysis of the HTS magnet was carried out together with the electromagnetic analysis. The effect of the cooling structures’ geometric parameters on the eddy-current losses was discussed. The methods of reducing the eddy-current loss were proposed. The analysis results demonstrate that the optimization of the geometric parameters would greatly benefit the reduction of the eddy-current losses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.