The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a novel coronavirus, was first identified after a cluster of cases in Wuhan, China in December 2019. Whether vertical transmission or placental pathology might occur following maternal infection during pregnancy remains unknown. This review aimed to summarise all studies that examined the placenta or neonates following infection with SARS-CoV-2, or closely related highly pathogenic coronavirus (SARS-CoV-1, or the Middle East respiratory syndrome coronavirus (MERS-CoV)). Structured literature searches found 50 studies that met the inclusion criteria. Twenty studies reported placental histopathology findings in third trimester placentas following maternal SARS-CoV-2 infection. Using the Amsterdam Consensus criteria to categorise the histopathology results, evidence of both fetal vascular malperfusion (35.3% of cases; 95% Confidence Interval (CI) 27.7–43.0%) and maternal vascular malperfusion (46% of cases; 95% CI 38.0–54.0%) were reported, along with evidence of inflammation in the placentas (villitis 8.7% cases, intervillositis 5.3% of cases, chorioamnionitis 6% of cases). The placental pathologies observed in SARS-CoV-2 were consistent with findings following maternal SARS-CoV-1 infection. Of those tested, a minority of neonates (2%) and placental samples tested positive for SARS-CoV-2 infection (21%). Limited conclusions can be drawn about the effect of maternal SARS-CoV-2 infection on placental pathology as most lack control groups and the majority of reports followed third trimester infection. Collaboration to maximise the number of samples examined will increase the reliability and generalisability of findings. A better understanding of the association between maternal SARS-CoV-2 infection and placental pathology will inform maternity care during the coronavirus pandemic.
Background Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a ‘snapshot’ of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (CFM) offers the potential to alleviate these issues by providing an objective and longitudinal overview of fetal status. Various CFM devices exist within literature; this review planned to provide a systematic overview of these devices, and specifically aimed to map the devices’ design, performance and factors which affect this, whilst determining any gaps in development. Methods A systematic search was conducted using MEDLINE, EMBASE, CINAHL, EMCARE, BNI, Cochrane Library, Web of Science and Pubmed databases. Following the deletion of duplicates, the articles’ titles and abstracts were screened and suitable papers underwent a full-text assessment prior to inclusion in the review by two independent assessors. Results The literature searches generated 4,885 hits from which 43 studies were included in the review. Twenty-four different devices were identified utilising four suitable CFM technologies: fetal electrocardiography, fetal phonocardiography, accelerometry and fetal vectorcardiography. The devices adopted various designs and signal processing methods. There was no common means of device performance assessment between different devices, which limited comparison. The device performance of fetal electrocardiography was reduced between 28 to 36 weeks’ gestation and during high levels of maternal movement, and increased during night-time rest. Other factors, including maternal body mass index, fetal position, recording location, uterine activity, amniotic fluid index, number of fetuses and smoking status, as well as factors which affected alternative technologies had equivocal effects and require further investigation. Conclusions A variety of CFM devices have been developed, however no specific approach or design appears to be advantageous due to high levels of inter-device and intra-device variability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.