Purpose Mammography is the only method that has been proven to detect breast microcalcifications (MCs), but the sensitivity of mammography varies according to breast density. This paper proposes an ultrasound (US) color Doppler twinkling artifact (CDTA) method with optimized transmit conditions to identify breast MCs without ionizing radiation. Methods The transmit conditions for US color Doppler imaging (CDI) were optimized to enhance the sensitivity of the twinkling artifact (TA) that arises from random scattering on rough surfaces of breast MCs. To validate the proposed breast MC detection method, a chicken breast phantom with MC particles (groups of particles <400 μm and <240 μm) was fabricated and scanned by a digital mammography system and an US research platform by an L11‐5v linear array probe with a three‐dimensional (3D) motion tracking system. Results From the phantom experiment, the proposed 3D CDTA imaging method with optimized transmit conditions (i.e., a center frequency of 5.0 MHz, an f‐number of 1.3, and a peak negative pressure of 1.83 MPa) successfully detected all 16 MC particles, comparable to detection with mammography. For a human breast surgical specimen in the ex vivo study, all 10 MC clusters, marked by a radiologist on the mammogram, were identified with the proposed 3D CDTA imaging method. Conclusions In the phantom and ex vivo breast specimen studies, the proposed 3D CDTA imaging method successfully detected MCs, and the spatial localization was highly correlated with the mammogram results. These results indicate that the proposed 3D CDTA imaging method has great potential for the detection of MCs without ionizing radiation.
BackgroundAortic pulse wave velocity (PWV) enables the direct assessment of aortic stiffness, which is an independent risk factor of cardiovascular (CV) events. The aim of this study is to evaluate the association between aortic PWV and CV risk model classified into three groups based on the Framingham risk score (FRS), i.e., low-risk (<10%), intermediate-risk (10~20%) and high-risk (>20%).MethodsTo noninvasively estimate local PWV in an abdominal aorta, a high-spatiotemporal resolution PWV measurement method (>1 kHz) based on wide field-of-view ultrafast curved array imaging (ufcPWV) is proposed. In the ufcPWV measurement, a new aortic wall motion tracking algorithm based on adaptive reference frame update is performed to compensate errors from temporally accumulated out-of-plane motion. In addition, an aortic pressure waveform is simultaneously measured by applanation tonometry, and a theoretical PWV based on the Bramwell-Hill model (bhPWV) is derived. A total of 69 subjects (aged 23–86 years) according to the CV risk model were enrolled and examined with abdominal ultrasound scan.ResultsThe ufcPWV was significantly correlated with bhPWV (r = 0.847, p < 0.01), and it showed a statistically significant difference between low- and intermediate-risk groups (5.3 ± 1.1 vs. 8.3 ± 3.1 m/s, p < 0.01), and low- and high-risk groups (5.3 ± 1.1 vs. 10.8 ± 2.5 m/s, p < 0.01) while there is no significant difference between intermediate- and high-risk groups (8.3 ± 3.1 vs. 10.8 ± 2.5 m/s, p = 0.121). Moreover, it showed a significant difference between two evaluation groups [low- (<10%) vs. higher-risk group (≥10%)] (5.3 ± 1.1 vs. 9.4 ± 3.1 m/s, p < 0.01) when the intermediate- and high-risk groups were merged into a higher-risk group.ConclusionThis feasibility study based on CV risk model demonstrated that the aortic ufcPWV measurement has the potential to be a new approach to overcome the limitations of conventional systemic measurement methods in the assessment of aortic stiffness.
Multifocal Doppler twinkling artifact (MDTA) imaging has shown high detection rates of microcalcifications in phantom studies. We aimed to evaluate its performance in detecting suspicious microcalcifications in comparison with mammography by using ex vivo breast cancer specimens. We prospectively included ten women with breast cancer that presented with calcifications on mammography. Both digital specimen mammography and MDTA imaging were performed for ex vivo breast cancer specimens on the day of surgery. Five breast radiologists marked cells that included suspicious microcalcifications (referred to as ‘positive cell’) on specimen mammographic images using a grid of 5-mm cells. Cells that were marked by at least three readers were considered as ‘consensus-positive’. Matched color Doppler twinkling artifact (CDTA) signals were compared between reconstructed US-MDTA projection images and mammographic images. The median detection rate for each case was 74.7% for positive cells and 96.7% for consensus-positive cells. Of the 10 cases, 90% showed a detection rate of ≥ 80%, with 50% of cases showing a 100% detection rate for consensus-positive cells. The proposed MDTA imaging method showed high performance for detecting suspicious microcalcifications in ex vivo breast cancer specimens, and may be a feasible approach for detecting suspicious breast microcalcifications with US.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.