BackgroundThree-dimensional time-resolved (4D) phase-contrast (PC) CMR can visualize and quantify cardiovascular flow but is hampered by long acquisition times. Acceleration with SENSE or k-t BLAST are two possibilities but results on validation are lacking, especially at 3 T. The aim of this study was therefore to validate quantitative in vivo cardiac 4D-acquisitions accelerated with parallel imaging and k-t BLAST at 1.5 T and 3 T with 2D-flow as the reference and to investigate if field strengths and type of acceleration have major effects on intracardiac flow visualization.MethodsThe local ethical committee approved the study. 13 healthy volunteers were scanned at both 1.5 T and 3 T in random order with 2D-flow of the aorta and main pulmonary artery and two 4D-flow sequences of the heart accelerated with SENSE and k-t BLAST respectively. 2D-image planes were reconstructed at the aortic and pulmonary outflow. Flow curves were calculated and peak flows and stroke volumes (SV) compared to the results from 2D-flow acquisitions. Intra-cardiac flow was visualized using particle tracing and image quality based on the flow patterns of the particles was graded using a four-point scale.ResultsGood accuracy of SV quantification was found using 3 T 4D-SENSE (r2 = 0.86, -0.7 ± 7.6%) and although a larger bias was found on 1.5 T (r2 = 0.71, -3.6 ± 14.8%), the difference was not significant (p = 0.46). Accuracy of 4D k-t BLAST for SV was lower (p < 0.01) on 1.5 T (r2 = 0.65, -15.6 ± 13.7%) compared to 3 T (r2 = 0.64, -4.6 ± 10.0%). Peak flow was lower with 4D-SENSE at both 3 T and 1.5 T compared to 2D-flow (p < 0.01) and even lower with 4D k-t BLAST at both scanners (p < 0.01). Intracardiac flow visualization did not differ between 1.5 T and 3 T (p = 0.09) or between 4D-SENSE or 4D k-t BLAST (p = 0.85).ConclusionsThe present study showed that quantitative 4D flow accelerated with SENSE has good accuracy at 3 T and compares favourably to 1.5 T. 4D flow accelerated with k-t BLAST underestimate flow velocities and thereby yield too high bias for intra-cardiac quantitative in vivo use at the present time. For intra-cardiac 4D-flow visualization, however, 1.5 T and 3 T as well as SENSE or k-t BLAST can be used with similar quality.
The breakup of 12 Be into 6 He 1 6 He and 4 He 1 8 He has been studied using a 378 MeV 12 Be beam inelastically excited by 12 C and ͑CH 2 ͒ n targets. The measurements indicate that breakup occurs from rotational states in the 10 to 25 MeV excitation energy interval, with spins in the range of 4h to 8h. The inferred moment of inertia is consistent with the cluster decay of an exotic molecular structure in 12 Be, which may be associated with an a-4n-a cluster configuration. [S0031-9007(99)08451-3]
BackgroundCardiovascular Magnetic Resonance (CMR) enables non-invasive quantification of cardiac output (CO) and thereby cardiac index (CI, CO indexed to body surface area). The aim of this study was to establish if CI decreases with age and compare the values to CI for athletes and for patients with congestive heart failure (CHF).MethodsCI was measured in 144 healthy volunteers (39 ± 16 years, range 21–81 years, 68 females), in 60 athletes (29 ± 6 years, 30 females) and in 157 CHF patients with ejection fraction (EF) below 40% (60 ± 13 years, 33 females). CI was calculated using aortic flow by velocity-encoded CMR and is presented as mean ± SD. Flow was validated in vitro using a flow phantom and in 25 subjects with aorta and pulmonary flow measurements.ResultsThere was a slight decrease of CI with age in healthy subjects (8 ml/min/m2 per year, r2 = 0.07, p = 0.001). CI in males (3.2 ± 0.5 l/min/m2) and females (3.1 ± 0.4 l/min/m2) did not differ (p = 0.64). The mean ± SD of CI in healthy subjects in the age range of 20–29 was 3.3 ± 0.4 l/min/m2, in 30–39 years 3.3 ± 0.5 l/min/m2, in 40–49 years 3.1 ± 0.5 l/min/m2, 50–59 years 3.0 ± 0.4 l/min/m2 and >60 years 3.0 ± 0.4 l/min/m2. There was no difference in CI between athletes and age-controlled healthy subjects but HR was lower and indexed SV higher in athletes. CI in CHF patients (2.3 ± 0.6 l/min/m2) was lower compared to the healthy population (p < 0.001). There was a weak correlation between CI and EF in CHF patients (r2 = 0.07, p < 0.001) but CI did not differ between patients with NYHA-classes I-II compared to III-IV (n = 97, p = 0.16) or patients with or without hospitalization in the previous year (n = 100, p = 0.72). In vitro phantom validation showed low bias (−0.8 ± 19.8 ml/s) and in vivo validation in 25 subjects also showed low bias (0.26 ± 0.61 l/min, QP/QS 1.04 ± 0.09) between pulmonary and aortic flow.ConclusionsCI decreases in healthy subjects with age but does not differ between males and females. We found no difference in CI between athletes and healthy subjects at rest but CI was lower in patients with congestive heart failure. The presented values can be used as reference values for flow velocity mapping CMR.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.