A 71-year-old woman, who had undergone mitral valve replacement procedure 2 years previously, presented with aortic and mitral prosthetic valve endocarditis. Preoperative examination demonstrated a wire-like structure coursing from the aortic bulb to the right carotid artery. The wire-like structure was removed during the mitral and aortic valve reoperation, and identified as an epicardial pacing wire, which was placed during the patients' first mitral valve operation. We suspect that the contaminated pacing wire migrated via the left atrium and left ventricle into the right carotid artery causing an infective endocarditis of the prosthetic mitral valve and the native aortic valve.
BackgroundMitral Valve Repair (MVRP) has been shown to be significantly superior to Mitral Valve Replacement (MVR). Since the majority of repairs involve the Posterior Mitral Leaflet (PML) and not the Anterior Mitral Leaflet (AML), the monocuspidalisation of the Mitral Valve (MV) can be achieved with a bio-posterior leaflet that imitates a closed PML. This approach may have the benefit of restoring the competence of the MV without reducing its effective orifice area.MethodsWe have used a new concept and device, the MitroFixTM, to correct MV regurgitation due to pathology of the PML. The device comes with functional sizers both of which have identical shape and size. This allows the surgeon to pre-test the success of the restoration. From December 2006 to October 2011, 51 MitroFixTM devices were implanted at three institutions.ResultsThe mean age of the patients (32 males and 19 females) was 67.7 years. 37 of them were in NYHA class III or IV and all patients suffered from severe mitral valve regurgitation (MR). 31 patients underwent combined surgery. Successful implantation of the MitroFix™ device was performed in 51/53 patients.Mean cross-clamp time was 63.6 min (range: 29-118 min). Six patients had additional reconstructive procedures of the AML (chordae transfer, neo-chordae, triangular resection). At discharge, 33 patients showed no MR in the TTE and 17 patients exhibited trivial (I) or moderate (II) MR. The mean gradient was 4.0 mmHg and mean EOA was 2.52cm^2 (range: 1.5-4.0cm2). All patients were classified as being in NYHA class I or II.ConclusionThe MitroFixTM Mitral Valve Restoration Device is a new concept that offers an effective treatment of MR. The restoration of the mitral valve with the MitroFix™ device offers the advantage of preserving the AML and providing good coaptation with a prosthetic PML. Importantly, this preliminary evaluation indicates a mean effective orifice area ( EOA ) of 2.5cm2 in MV receiving a MitroFix™ device, witch is higher than EOA resulting from MVR or MVRP. The present study has also shown that severe regurgitation due to ischemic/rheumatic MR, endocarditis and complex prolapse of the PML are clear candidates for correction with the MitroFix™. Larger studies and a longer follow up period are needed to validate these promising results.
For implantable cardioverter defibrillator a 10 J safety margin between the defibrillation threshold (DFT) and the maximum output of the device is intended. In complex cases, the additional placement of a subcutaneous array lead is a common strategy for lowering the DFT. We report the successful use of transvenous coil electrodes as single element subcutaneous array leads in order to lower the DFT.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.