ICG R15 is reliable within one group at defined perfusion rates. Doubled perfusion rates contribute to higher ICG clearance. For clinical application we would like to suggest considering cardiac output of the patient for interpretation of ICG ratios.
Background: Laparoscopic resections of parenchymal organs are increasingly performed. However, little is known about the effects of laparoscopic fibrin sealant spray applications on intraabdominal pressure (IAP) and hemodynamics. Methods: Cardiac and pulmonary monitoring was performed via two central venous pressure lines in the thoracic and abdominal vena cava, a pulmonary artery catheter, and a peripheral artery line. Air was sprayed into the abdomen at pressures of 2, 3, and 4 bar for 30 s. According to the group, a valve on a trocar was open or closed. To optimize fibrin sealant application, the sealant was sprayed at three different application pressures (2, 2.5, and 3 bar) and distances (2, 3.5, and 5 cm). Results: All spray simulations caused a significant increase in the IAP. During the first 10 s of spraying, the IAP increase was 5 mmHg or less, but rose rapidly during the last 20 s of spraying. The IAP increase resulted in decreased pulmonary compliance. Pulmonary resistance and the central venous pressures of both the thoracic and abdominal vena cava increased. At application pressures of 3 and 4 bar, the IAP increase was greater than 2 bar of pressure, reaching IAP values exceeding 35 mmHg. Spray mist formation was primarily dependent on application pressure, whereas clot formation and surface coverage depended on both application pressure and distance. The best results were achieved with an application pressure of 2.5 bar and a distance of 5 cm from the surface.Conclusions: This study shows that fibrin sealants can be used safely in laparoscopic procedures. Keeping the spray periods short and allowing air to escape from the abdomen can minimize the IAP increase. According to our results, a laparoscopic spray application of fibrin sealant should start with an insufflation pressure of 10 mmHg, an application pressure of 2.5 bar, and an application distance of 5 cm with a valve on the trocar left open.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.