Although the steel-concrete interface (SCI) is widely recognized to influence the durability of reinforced concrete, a systematic overview and detailed documentation of the various aspects of the SCI are lacking. In this paper, we compiled a comprehensive list of possible local characteristics at the SCI and reviewed available information regarding their properties as well as their occurrence in engineering structures and in the laboratory. Given the complexity of the SCI, we suggested a systematic approach to describe it in terms of local characteristics and their physical and chemical properties. It was found that the SCI exhibits significant spatial inhomogeneity along and around as well as perpendicular to the reinforcing steel. The SCI can differ strongly between different engineering structures and also between different members within a structure; particular differences are expected between structures built before and after the 1970/1980s. A single SCI representing all on-site conditions does not exist. Additionally, SCIs in common laboratory-made specimens exhibit significant differences compared to engineering structures. Thus, results from laboratory studies and from practical experience should be applied to engineering structures with caution. Finally, recommendations for further research are made. This report was prepared by the working group within RILEM TC 262-SCI, and further reviewed and approved by all members of the RILEM TC 262-SCI.
This paper reports results from experiments aimed at better understanding the influence of fibre dosage and fibre geometry on the AC frequency needed to determine the DC resistivity of cementitious materials containing steel fibres. Impedance spectroscopy and DC galvanodynamic measurements were performed on mortar prisms with varying fibre reinforcement to determine the matrix resistivity (related to ionic current within the pore solution) and composite resistivity (accounting for both ionic current and electronic current through the fibres). The results showed that adding steel fibres did not significantly affect the DC nor the AC matrix resistivity of the mortar prisms. However, the steel fibres yielded a drastic reduction of the frequency associated to the AC matrix resistivity from ~1 kHz in plain mortar to ~1 Hz in steel fibre reinforced mortar. These findings revealed the need to adequately adjust the frequency in AC resistivity measurements of steel fibre reinforced cementitious materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.