High tibial osteotomy correction angle calculation is a process that is usually performed manually or in a semi-automated way. The process, according to the Miniaci method, is divided into several stages to find specific points: the center of the femoral head, the edges of the tibial plateau, the Fujisawa point, the center of the ankle joint, and the Hinge point. In this paper, we proposed an end-to-end approach that consists of different techniques for finding each point. We used YOLOv4 to detect regions of interest. To identify the center of the femoral head, we used the YOLOv4 and the Hough transform. For the other points, we used a combined method of YOLOv4 with the ASM/AAM algorithm and YOLOv4 with image processing algorithms. Our fully-automated method achieved a mean error rate of 0.5$$^{\circ }$$ ∘ (0$$^{\circ }$$ ∘ –2.76$$^{\circ }$$ ∘ ) ICC 0.99 (0.98–0.99) 95% CI on our own dataset of standing long-leg Anterior Posterior view X-rays. This might be the first method that automatically calculates the correction angle of high tibial osteotomy.
High tibial osteotomy correction angle calculation is a process that is usually performed manually or in a semi-automated way. The process, according to the Miniaci method, is divided into several stages to find specific points: the center of the femoral head, the edges of the tibial plateau, the Fujisawa point, the center of the ankle joint, and the Hinge point. In this paper, we proposed an end-to-end approach that consists of different techniques for finding each point. We used YOLOv4 to detect regions of interest. To identify the center of the femoral head, we used the YOLOv4 and the Hough transform. For the other points, we used a combined method of YOLOv4 with the ASM/AAM algorithm and YOLOv4 with image processing algorithms. Our fully-automated method achieved a mean error rate of 0.5◦ (0-2.76◦) ICC 0.99 (0.98-0.99) 95%CI on our own dataset of standing long-leg Anterior Posterior view X-rays. This might be the first method that automatically calculates the correction angle of high tibial osteotomy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.