Hygienic Performance of Commercial Dishwashers with Water-Change System -A nE x p er i m en t a lS t u d y Commercial dishwashers are used in community facilities such as hospitals, refectories, nursing homes or food services. In this area, kitchen and food hygiene is of great importance to ensure consumer health. The aim of this study was to verify the hygienic performance of commercial dishwashers with a water-change system by use of bioindicators. This test method is described in DIN SPEC 10534. Micrococcus luteus was used as the test germ instead of Enterococcus faecium as it imposes no pathogenic risk. Micrococcus luteus was identified in initial studies as an appropriate test germ for hygiene studies. Cleaning and rinsing temperatures and holding time of the cleaning program were varied. High rinsing temperature with a constant cleaning temperature and high cleaning temperatures with a constant rinsing temperature led to a reduction of the viable cell count. Increasing the cleaning temperature resulted in a higher decrease of the viable cell count than increasing the rinsing temperature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.