BackgroundRe-contouring of structures on consecutive planning computed tomography (CT) images for patients that exhibit anatomical changes is elaborate and may negatively impact the turn-around time if this is required for many patients. This study was therefore initiated to validate the accuracy and usefulness of automatic contour propagation for head and neck cancer patients using SmartAdapt® which is the deformable image registration (DIR) application in Varian’s Eclipse™ treatment planning system.MethodsCT images of eight head and neck cancer patients with multiple planning CTs were registered using SmartAdapt®. The contoured structures of target volumes and OARs of the primary planning CT were deformed accordingly and subsequently compared with a reference structure set being either: 1) a structure set independently contoured by the treating Radiation Oncologist (RO), or 2) the DIR-generated structure set after being reviewed and modified by the RO.ResultsApplication of DIR offered a considerable time saving for ROs in delineation of structures on CTs that were acquired mid-treatment. Quantitative analysis showed that 84% of the volume of the DIR-generated structures overlapped with the independently re-contoured structures, while 94% of the volume overlapped with the DIR-generated structures after review by the RO. This apparent intra-observer variation was further investigated resulting in the identification of several causes. Qualitative analysis showed that 92% of the DIR-generated structures either need no or only minor modification during RO reviews.ConclusionsSmartAdapt is a powerful tool with sufficient accuracy that saves considerable time in re-contouring structures on re-CTs. However, careful review of the DIR-generated structures is mandatory, in particular in areas where tumour regression plays a role.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.