Objectives N95 filtering facepiece respirators (N95 FFRs) and surgical masks are comprised of multiple layers of nonwoven polypropylene. Tight-fitting N95 FFRs are respiratory protective devices (RPDs) designed to efficiently filter aerosols. During the COVID-19 pandemic, health care workers (HCWs) throughout the world continue to face shortages of disposable N95 FFRs. Existing version of widely available FDA cleared loose-fitting surgical masks with straps do not provide reliable protection against aerosols. We tested the faceseal of a modified strapless form-fitting sealed version of surgical mask using quantitative fit testing (QNFT) and compared the performance of this mask with that of N95 FFRs and unmodified loose-fitting surgical masks. Methods Twenty HCWs participated in the study (10 women; 10 men; age 23–59 years). To create the sealed surgical masks, we removed the straps from loose-fitting surgical masks, made new folds, and used adhesive medical tape to secure the new design. All participants underwent QNFT with a loose-fitting surgical mask, the sealed surgical mask, and an N95 FFR; fit factors were recorded. Each QNFT was performed using a protocol of four exercises: (i) bending over, (ii) talking, (iii) moving head side to side, and (iv) moving head up and down. When the overall fit factor for the sealed surgical mask or N95 FFR was <100, the participant retook the test. Participants scored the breathability and comfort of the sealed surgical mask and N95 FFR on a visual analog scale (VAS) ranging from 0 (unfavorable) to 10 (favorable). Results The median fit factor for the sealed surgical mask (53.8) was significantly higher than that of the loose-fitting surgical mask (3.0) but lower than that of the N95 FFR (177.0) (P < 0.001), equating to significantly lower inward leakage of ambient aerosols (measuring 0.04–0.06 µm) with the sealed surgical mask (geometric mean 1.79%; geometric standard deviation 1.45%; range 0.97–4.03%) than with the loose-fitting surgical mask (29.5%; 2.01%; 25–100.0%) but still higher than with the N95 FFR (0.66%; 1.46%; 0.50–1.97%) (P < 0.001). Sealed surgical masks led to a marked reduction (range 60–98%) in inward leakage of aerosols in all the participants, compared to loose-fitting surgical masks. Among the exercises, talking had a greater effect on reducing overall fit factor for the sealed surgical mask than for the N95 FFR; when talking was excluded, the fit factor for the sealed surgical mask improved significantly (median 53.8 to 81.5; P < 0.001). The sealed surgical mask, when compared with the N95 FFR, offered better reported breathability (median VAS 9 versus 5; P < 0.001) and comfort (9 versus 5; P < 0.001). Conclusions Widely available loose-fitting surgical masks can be easily modified to achieve faceseal with adhesives. Unlike loose-fitting surgical masks, sealed surgical masks can markedly reduce inward leakage of aerosols and may therefore offer useful levels of respiratory protection during an extreme shortage of N95 FFRs and could benefit HCWs who cannot comply with N95 FFRs due to intolerance. However, because a wide range of surgical masks is commercially available, individual evaluation of such masks is highly recommended before sealed versions are used as RPDs.
Diverticulosis remains the commonest cause for acute lower gastrointestinal tract bleeding (GIB). Conservative management is initially sufficient for most patients, followed by elective diagnostic tests. However, if acute lower GIB persists, it can be investigated with colonoscopy, CT angiography (CTA), or red blood cell (RBC) scan. Colonoscopy can identify the site and cause of bleeding and provide
Central venous occlusion is a common condition in certain patient populations, with significant associated morbidity. Symptoms range from mild arm swelling to respiratory distress and can be particularly troublesome in the end stage renal disease population when related to dialysis access and function. Crossing completely occluded vessels is often the most challenging step and various techniques exist to accomplish this. Traditionally, blunt and sharp recanalization techniques are used to cross occluded vessels and are described in detail. Even with experienced providers there are lesions which prove to be too difficult and are refractory to traditional approaches. We discuss advanced techniques such as with radiofrequency guidewires as well as newer technologies which offer an alternative pathway to re-establishing access. These emerging methods have demonstrated procedural success in the majority of cases where traditional techniques were futile. Following recanalization, angioplasty with or without stenting is typically performed and restenosis is a commonly encountered complication. We discuss angioplasty and the emerging use of drug-eluting balloons in venous thrombosis. Subsequently, in regards to stenting we discuss the indications and multitude of available types including novel venous stents with their respective strengths and drawbacks. Potential feared complications such as venous rupture with balloon angioplasty and stent migration are discussed along with our recommendations to reduce their risk of occurrence and promptly manage them when they do unfortunately occur.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.