Background:An anterior cruciate ligament (ACL) rupture often occurs during rotational trauma to the knee and may be associated with damage to extracapsular knee rotation–stabilizing structures such as the anterolateral ligament (ALL).Purpose:To investigate ex vivo knee laxity in 6 degrees of freedom with and without ALL reconstruction as a supplement to ACL reconstruction.Study Design:Controlled laboratory study.Methods:Cadaveric knees (N = 8) were analyzed using dynamic radiostereometry during a controlled pivotlike dynamic movement simulated by motorized knee flexion (0° to 60°) with 4-N·m internal rotation torque. We tested the cadaveric specimens in 5 successive ligament situations: intact, ACL lesion, ACL + ALL lesion, ACL reconstruction, and ACL + ALL reconstruction. Anatomic single-bundle reconstruction methods were used for both the ACL and the ALL, with a bone-tendon quadriceps autograft and gracilis tendon autograft, respectively. Three-dimensional kinematics and articular surface interactions were used to determine knee laxity.Results:For the entire knee flexion motion, an ACL + ALL lesion increased the mean knee laxity (P < .005) for internal rotation (2.54°), anterior translation (1.68 mm), and varus rotation (0.53°). Augmented ALL reconstruction reduced knee laxity for anterior translation (P = .003) and varus rotation (P = .047) compared with ACL + ALL–deficient knees. Knees with ACL + ALL lesions had more internal rotation (P < .001) and anterior translation (P < .045) at knee flexion angles below 40° and 30°, respectively, compared with healthy knees. Combined ACL + ALL reconstruction did not completely restore native kinematics/laxity at flexion angles below 10° for anterior translation and below 20° for internal rotation (P < .035). ACL + ALL reconstruction was not found to overconstrain the knee joint.Conclusion:Augmented ALL reconstruction with ACL reconstruction in a cadaveric setting reduces internal rotation, varus rotation, and anterior translation knee laxity similar to knee kinematics with intact ligaments, except at knee flexion angles between 0° and 20°.Clinical Relevance:Patients with ACL injuries can potentially achieve better results with augmented ALL reconstruction along with ACL reconstruction than with stand-alone ACL reconstruction. Furthermore, dynamic radiostereometry provides the opportunity to examine clinical patients and compare the recontructed knee with the contralateral knee in 6 degrees of freedom.
ObjectivesStatic radiostereometric analysis (RSA) using implanted markers is considered the most accurate system for the evaluation of prosthesis migration. By using CT bone models instead of markers, combined with a dynamic RSA system, a non-invasive measurement of joint movement is enabled. This method is more accurate than current 3D skin marker-based tracking systems. The purpose of this study was to evaluate the accuracy of the CT model method for measuring knee joint kinematics in static and dynamic RSA using the marker method as the benchmark.MethodsBone models were created from CT scans, and tantalum beads were implanted into the tibia and femur of eight human cadaver knees. Each specimen was secured in a fixture, static and dynamic stereoradiographs were recorded, and the bone models and marker models were fitted to the stereoradiographs.ResultsResults showed a mean difference between the two methods in all six degrees of freedom for static RSA to be within -0.10 mm/° and 0.08 mm/° with a 95% limit of agreement (LoA) ranging from ± 0.49 to 1.26. Dynamic RSA had a slightly larger range in mean difference of -0.23 mm/° to 0.16 mm/° with LoA ranging from ± 0.75 to 1.50.ConclusionsIn a laboratory-controlled setting, the CT model method combined with dynamic RSA may be an alternative to previous marker-based methods for kinematic analyses.Cite this article: K. Stentz-Olesen, E. T. Nielsen, S. De Raedt, P. B. Jørgensen, O. G. Sørensen, B. L. Kaptein, M. S. Andersen, M. Stilling. Validation of static and dynamic radiostereometric analysis of the knee joint using bone models from CT data. Bone Joint Res 2017;6:376–384. DOI: 10.1302/2046-3758.66.BJR-2016-0113.R3.
The ALL was confirmed as a stabiliser of internal rotation in ACL-deficient knees. However, reconstructing the ALL using a gracilis autograft tendon did not decrease the internal rotation laxity in the ACL-reconstructed knee. Based on the results of this study, we do not recommend reconstructing the ALL in ACL-reconstructed knees to decrease internal knee laxity.
Complex radial head fracture and elbow instability can be treated with radial head arthroplasty. Good clinical results have been described after this surgical treatment. However, the revision and complication rate reported in the literature is concerning. This might be due to altered kinematics after radial head arthroplasty. Eight human native elbows were examined with dynamic radiostereometric analysis and compared with a radial head arthroplasty. Translations of the radial head in the x‐, y‐, and z‐directions relative to the humerus and the ulna were measured. The radiocapitellar joint pressure was measured using a pressure sensor. The tension within the interosseous membrane was measured using a custom‐made strain gauge. After radial head arthroplasty, the radial head was displaced approximately 1.8 mm medially and 1.4 mm distally at the starting point. During unloaded flexion motion the difference in all translations between the native radial head and the radial head arthroplasty was less than 1 mm (95% confidence interval [CI] ± 0.5 mm) (p = 0.001). With loading the difference was less than 1.5 mm (95% CI ± 1.5 mm) (p = 0.001). The mean difference in radiocapitellar joint contact pressure was less than 0.30 MPa (95% CI ± 0.40 MPa) (p = 0.001) during unloaded flexion motion. There were only submillimetre kinematic changes and small changes in joint pressure and interosseous membrane tension after the insertion of a radial head arthroplasty in an experimental setting. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:510–522, 2020
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.