ObjectiveSputum smear microscopy reading errors are likely to result in failure to detect persons with infectious TB. This study was intended to review misdiagnosis of pulmonary TB and associated factors in peripheral laboratories.ResultsDuring the study period 1033 (10.5%) sputum smear positive and 8783 (89.5%) smear negative slides were reported by peripheral laboratories. The slides were re-read by the central referral laboratories (CRLs) as the reference standard reading. Of 1033 positive slides reported by peripheral laboratories, 25 (2.4%) were false positive. Out of 8783 smear negative slides reported by peripheral laboratories, 35 (0.4%) were false negative. The sensitivity, specificity, positive predictive value and negative predictive value of peripheral laboratories were 96.64, 99.72, 97.58, and 99.61% respectively. The peripheral laboratories and CRLs have an observed agreement (Po) of 0.9939. Of 135 peripheral laboratories, 93 (68.9%) read negative and positive slides correctly, 49 (36.3%) did not have lens cleaning tissue papers, 11 (8.1%) lacked frosted slides, and 14 (10.4%) had shortage of reagents. As conclusions, the peripheral laboratories and CRLs had high agreement for sputum smear microscopy reading. However, a few TB cases were misdiagnosed despite having the disease; these individuals might continue to spread the infection in the community.
Background: Food contact surfaces are surfaces that encounter food for humans. It can harbor and introduce pathogens into food. Objective: The aim of this study was to assess the microbiological quality of food contact surfaces (utensils) from hotels and restaurants in Addis Ababa. Methods: We used cross-sectional study design in which 12 hotels and 28 restaurants were randomly selected in Addis Ababa. Swab samples from utensils of hotels and restaurants were collected (i.e. four utensils from each establishment) and analyzed over the period of three months resulting in a total of 160 swab samples. Result: Among the hotel and restaurant utensils the highest median count of log total coliform was obtained on trays (5.93log10CFU/100cm2 in hotels and 5.00log10CFU/100 cm2, in restaurants). Faecal coliform and E.coli was detected in 14.37% and 3.12% of utensils, respectively. The highest median count of log S.aureus was 5.95log10CFU/100cm2 on tray in hotel and 5.57log10CFU/100cm2 on dipper in restaurant and, the median counts of log APC was 9.37log10CFU/100cm2 on tray in Hotel and 8.51log10CFU/100cm2 on spoon in restaurant. Conclusion: The finding showed that there is high microbial load and inadequacy of washing and cleaning services in hotels and restaurants in Addis Ababa. Hence, there is a need to strengthen monitoring and supervision system is hotels and restaurants.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.