Objectives The aim of this study was to report complications, as well as short- and long-term clinical outcomes of cats suffering from surgically reduced intussusception with and without enteroplication. Methods Medical records of cats presented at our institution with intussusception between 2001 and 2016 were reviewed. The following data were retrieved: signalment; history; physical examination; diagnostic imaging, surgical and histological findings; and outcomes. Animals were grouped as with or without enteroplication. Duration of surgery, survival, complication and recurrence rates, duration of hospitalisation, and short- and long-term outcomes were compared. Results Cats with intussusception presented with unspecific type and duration of clinical signs. Male or male castrated cats and Maine Coons were over-represented in both groups. Enteroplication was performed in 48% (10/21) of the cats. Cats in the enteroplication group were significantly younger than those in the non-enteroplication group ( P = 0.023). Duration of surgery, time of hospitalisation, complication rate and outcomes did not differ between the two groups. Two complications in the short term and one complication in the long term were possibly associated with enteroplication. A recurrence of intussusception was seen in 2/17 cats approximately 12 months after initial surgery, both previously treated with enteroplication. Conclusions and relevance Although the number of cases was limited, our results suggest that enteroplication should be cautiously performed in cats with intussusception as it may be associated with major complications in the short and long term, and its efficacy remains unclear. Based on this study, the need for enteroplication in cats following a correction of intussusception could be questioned.
ObjectiveTo evaluate the penetration depth (VNPD) of 2 disposable Veress needles (VN) at 4 insertion sites in the abdomen.Study designDescriptive study.Sample populationCanine cadavers (n = 22, 6 for confirmation of the test methods and 16 for the comparative study).MethodsTwo disposable VN (VN A and VN B) were inserted at 4 sites (9th intercostal space [ICS] and preumbilical, paraumbilical, and subumbilical sites) in dorsally recumbent dogs by using a hand‐cranked jig. The VNPD was measured as the distance traveled by the VN between the subcutaneous tissue and the perforation of the peritoneum on the basis of audible clicks and visible feedback from the VN. The effects of the VN type and insertion site on the VNPD were analyzed by using a linear mixed‐effects model.ResultsVNPD varied between insertion sites (P = .01) and VN (P < .01). The VNPD was less at the 9th ICS than at the preumbilical, paraumbilical, and subumbilical sites. The maximal magnitude of change was 7.4 mm. Veress needle B (with a low spring rate, lower forces, and a back‐cut bevel design) penetrated farther than VN A (with a high spring rate, high forces, and a lancet‐type bevel) at 3 of 4 insertion sites. The maximal magnitude of change was 6.8 mm.ConclusionVeress needle penetration depth varied between VN designs but was the least at the 9th ICS in canine cadavers.Clinical significanceInsertion of a VN at the 9th ICS is recommended to minimize its penetration into the abdomen. Associations between VNPD and mechanical factors, such as the sharpness and spring rate of VN, warrant additional research.
Synthetic anatomical reconstruction of extensive, oval osteochondrosis dissecans (OCD) defects remains a challenge due to the ‘one shape fits all’ design of commercial round implants. This is further complicated by the inherent inaccuracy of free-hand implant positioning procedures. A 6-month-old German Shepherd presented with a 15 × 7.8 × 4.3 mm OCD defect at the lateral femoral condyle. A synthetic patient-specific implant (PSI) was designed, using the contralateral unaffected condyle as a template. Reaming of the implant bed was fully guided using a set of three-dimensional-printed drill guides. The implant, consisting of a titanium base and a polycarbonate urethane bearing surface, was press-fit into place. Temporary meniscal release of the cranial meniscal horn was repaired, followed by routine closure and postoperative care. The combination of PSI and matching drill guides resulted in an accurate restoration of the normal joint surface at the former defect area. At 6-week and 18-month follow-ups, mild joint effusion, unexpected soft tissue mineralization and a small joint mouse were present. No other complications were encountered, and the dog was clinically lameness-free. At 6 weeks and 6 months, computerized gait analysis documented increased loading of the affected limb from 36% preoperatively to 42 and 40%, on follow-up, respectively. Body weight distribution between both hindlimbs was nearly equal at the 6-month control with 1% difference in loading. Osteochondral resurfacing using a PSI appears to be a promising treatment option for large stifle OCD lesions in which other treatment modalities may not be eligible.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.