Systemic inflammatory response syndrome (SIRS) is a common complication after cardiovascular surgery that in severe cases can lead to multiple organ dysfunction syndrome and even death. We therefore set out to identify reliable early biomarkers for SIRS in a prospective small patient study for timely intervention. 21 Patients scheduled for planned cardiovascular surgery were recruited in the study, monitored for signs of SIRS and blood samples were taken to investigate biomarkers at pre-assigned time points: day of admission, start of surgery, end of surgery, days 1, 2, 3, 5 and 8 post surgery. Stored plasma and cryopreserved blood samples were analyzed for cytokine expression (IL1β, IL2, IL6, IL8, IL10, TNFα, IFNγ), other pro-inflammatory markers (sCD163, sTREM-1, ESM-1) and response to endotoxin. Acute phase proteins CRP, PCT and pro-inflammatory cytokines IL6 and IL8 were significantly increased (p<0.001) at the end of surgery in all patients but could not distinguish between groups. Normalization of samples revealed significant increases in IL1β changes (p<0.05) and decreased responses to endotoxin (p<0.01) in the SIRS group at the end of surgery. Soluble TREM-1 plasma concentrations were significantly increased in patients with SIRS (p<0.01). This small scale patient study could show that common sepsis markers PCT, CRP, IL6 and TNFα had low predictive value for early diagnosis of SIRS after cardiovascular surgery. A combination of normalized IL1β plasma levels, responses to endotoxin and soluble TREM-1 plasma concentrations at the end of surgery are predictive markers of SIRS development in this small scale study and could act as an indicator for starting early therapeutic interventions.
Hemocompatibility and cytocompatibility of biomaterials codetermine the success of tissue engineering applications. DNA, the natural component of our cells, is an auspicious biomaterial for the generation of designable scaffolds with tailorable characteristics. In this study, a combination of rolling circle amplification and multiprimed chain amplification is used to generate hydrogels at centimeter scale consisting solely of DNA. Using an in vitro rotation model and fresh human blood, the reaction of the hemostatic system on DNA hydrogels is analyzed. The measurements of hemolysis, platelets activation, and the activation of the complement, coagulation, and neutrophils using enzyme-linked immunosorbent assays demonstrate excellent hemocompatibility. In addition, the cytocompatibility of the DNA hydrogels is tested by indirect contact (agar diffusion tests) and material extract experiments with L929 murine fibroblasts according to the ISO 10993-5 specifications and no negative impact on the cell viability is detected. These results indicate the promising potential of DNA hydrogels as biomaterials for versatile applications in the field of regenerative medicine.
Pyrogens are components of microorganisms, like bacteria, viruses or fungi, which can induce a complex inflammatory response in the human body. Pyrogen contamination on medical devices prior operation is still critical and associated with severe complications for the patients. The aim of our study was to develop a reliable test, which allows detection of pyrogen contamination on the surface of medical devices. After in vitro pyrogen contamination of different medical devices and incubation in a rotation model, the human whole blood monocyte activation test (MAT), which is based on an IL-1β-specific ELISA, was employed. Our results show that when combining a modified MAT protocol and a dynamic incubation system, even smallest amounts of pyrogens can be directly detected on the surface of medical devices. Therefore, screening of medical devices prior clinical application using our novel assay, has the potential to significantly reduce complications associated with pyrogen-contaminated medical devices.
Extracorporeal membrane oxygenation (ECMO) is a pivotal bridge to recovery for cardiopulmonary failure in children. Besides its life-saving quality, it is often associated with severe system-related complications, such as hemolysis, inflammation, and thromboembolism. Novel oxygenator and pump systems may reduce such ECMO-related complications. The ExMeTrA oxygenator is a newly designed pediatric oxygenator with an integrated pulsatile pump minimizing the priming volume and reducing the surface area of blood contact. The aim of our study was to investigate the feasibility and safety of this new ExMeTrA (expansion mediated transport and accumulation) oxygenator in an animal model. During 6 h of extracorporeal circulation (ECC) in pigs, parameters of the hemostatic system including coagulation, platelets and complement activation, and flow rates were investigated. A nonsignificant trend in C3 consumption, thrombin-antithrombin-III (TAT) complex formation and a slight trend in hemolysis were detected. During the ECC, the blood flow was constantly at 500 ml/min using only flexible silicone tubes inside the oxygenator as pulsatile pump. Our data clearly indicate that the hemostatic markers were only slightly influenced by the ExMeTrA oxygenator. Additionally, the oxygenator showed a constant quality of blood flow. Therefore, this novel pediatric oxygenator shows the potential to be used in pediatric and neonatal support with ECMO.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.