Heparin kinetics were determined in four normal subjects, each of whom received three different doses (25, 50, and 75 units/kg body weight) by intravenous injection. Multiple blood samples were collected after each dose and each plasma sample was assayed for heparin activity using three different assay methods. Two of these assays are based on coagulation tests, i.e., activated partial thromboplastin time and thrombin time, while the third is based on chemical neutralization of heparin using hexadimethrine bromide. Heparin kinetics showed pronounced dose-dependent changes, irrespective of the assay method used, which were characterized by increasing biologic half-life and decreasing total clearance (Cl) with increasing dose. No changes were noted in apparent volume of distribution (Vd). This data also showed that there were differences in kinetic parameters of heparin depending on the assay method. In general, values for total Cl and apparent Vd based on chemical neutralization were approximately 1.5 to 2.0 times these parameters based on coagulation tests. We conclude that the immediate mechanism of the dose-dependent heparin kinetics is decreasing total clearance with increasing dose and suggest that in vivo activation of the anticoagulant properties of heparin may explain the assay-dependent kinetics.
The kinetics of the antiplatelet drug dipyridamole were studied in six normal subjects (three men and three women) who were ages 22 to 34 yr old. Each received 20 mg IV and four also took a 50-mg oral dose. Blood samples were collected after each dose for a period of 3 days and concentrations of dipyridamole were measured by a sensitive and specific high-performance liquid chromatographic assay. Concentrations after the intravenous dose showed a triexponential decline with a terminal half-life of 11.6 +/- 2.2 hr (x +/- SD). Total plasma clearance was 8.27 +/- 1.82 1/hr and the apparent volume of distribution was 141 +/- 51 1. Concentrations rose 6 to 10 hr after intravenous dipyridamole in each female subject, but not in the male subjects. Dipyridamole blood/plasma concentration ratio changed from an average of 0.7 over the first hour to 1.2 after 5 hr after the intravenous dose. There was an absorption lag time ranging from 34 to 75 min after the oral dose; concentrations peaked at about 2 to 2.5 hr after the dose. The percentage of unbound drag in plasma was 0.88 +/- 0.24%. Systemic availability of the end oral dose was 43 +/- 13%. These results suggest widely varying concentrations in patients receiving the drug, and raise questions about the current clinical practice of using empirical dosage schedules.
The significance of baseline coagulation times and plasma concentrations of serine protease inhibitors as determinants of the relationship between heparin activity and its anticoagulant effect has been investigated in vitro. Citrated plasma was prepared from blood obtained from 20 normal subjects, and heparin added to yield concentrations ranging from 0.05 to 1.5 units/ml. The anticoagulant effect was determined by the activated partial thromboplastin time (APTT) and thrombin time (TT). An excellent linear relationship was observed between the natural logarithms (ln) of the coagulation times and heparin activity. Baseline APTT values ranged from 28.4 to 59.7 s and the slope values for the ln APTT vs heparin curves ranged from 1.488 to 3.427 ml/unit. Similar range was observed in the slope values for the ln TT vs heparin curves. There was a highly significant positive correlation between the ln APTT vs heparin slope values and the baseline APTT values (r: 0.905; p less than 0.001). There was also a weak but statistically significant positive correlation between plasma concentrations of alpha 2 macroglobulin and baseline APTT values (0.02 greater than 0 greater than 0.01) and slope values of the ln APTT vs heparin curves (0.02 greater than p greater than 0.01). Furthermore, there was a statistically significant positive correlation between plasma concentrations of alpha 1 antitrypsin and baseline TT values (0.05 greater than p greater than 0.02) and slope values of the 1n TT vs heparin (0.02 greater than p greater than 0.01). Neither baseline APTT and TT values nor slope values of the ln APTT and TT vs heparin curves were statistically significantly related to plasma concentrations of antithrombin III, fibrinogen, or alpha 1 acid glycoprotein. This study has demonstrated that baseline APTT is a major determinant of the anticoagulant response to heparin in vitro, as determined by that same coagulation test, and it illustrates that there is a wide intersubject variation in the anticoagulant response to heparin in vitro.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.