ObjectivesThe CHARM-01 study characterized the safety, acceptability, pharmacokinetics (PK), and pharmacodynamics (PD) of three tenofovir (TFV) gels for rectal application. The vaginal formulation (VF) gel was previously used in the CAPRISA 004 and VOICE vaginal microbicide Phase 2B trials and the RMP-02/MTN-006 Phase 1 rectal safety study. The reduced glycerin VF (RGVF) gel was used in the MTN-007 Phase 1 rectal microbicide trial and is currently being evaluated in the MTN-017 Phase 2 rectal microbicide trial. A third rectal specific formulation (RF) gel was also evaluated in the CHARM-01 study.MethodsParticipants received 4 mL of the three TFV gels in a blinded, crossover design: seven daily doses of RGVF, seven daily doses of RF, and six daily doses of placebo followed by one dose of VF, in a randomized sequence. Safety, acceptability, compartmental PK, and explant PD were monitored throughout the trial.ResultsAll three gels were found to be safe and acceptable. RF and RGVF PK were not significantly different. Median mucosal mononuclear cell (MMC) TFV-DP trended toward higher values for RF compared to RGVF (1136 and 320 fmol/106 cells respectively). Use of each gel in vivo was associated with significant inhibition of ex vivo colorectal tissue HIV infection. There was also a significant negative correlation between the tissue levels of TFV, tissue TFV-DP, MMC TFV-DP, rectal fluid TFV, and explant HIV-1 infection.ConclusionsAll three formulations were found to be safe and acceptable. However, the safety profile of the VF gel was only based on exposure to one dose whereas participants received seven doses of the RGVF and RF gels. There was a trend towards higher tissue MMC levels of TFV-DP associated with use of the RF gel. Use of all gels was associated with significant inhibition of ex vivo tissue HIV infection.Trial RegistrationClinicalTrials.gov NCT01575405
ObjectivesThe purpose of Project Gel was to determine the safety and acceptability of rectal microbicides in young men who have sex with men (MSM) and transgender women (TGW) at risk of HIV infection.MethodsMSM and TGW aged 18–30 years were enrolled at three sites; Pittsburgh, PA; Boston, MA; and San Juan, PR. Stage 1A was a cross-sectional assessment of sexual health and behavior in MSM and TGW. A subset of participants from Stage 1A were then enrolled in Stage 1B, a 12-week evaluation of the safety and acceptability of a placebo rectal gel. This was followed by the final phase of the study (Stage 2) in which a subset of participants from Stage 1B were enrolled into a Phase 1 rectal safety and acceptability evaluation of tenofovir (TFV) 1% gel.Results248 participants were enrolled into Stage 1A. Participants’ average age was 23.3 years. The most common sexually transmitted infection (STIs) at baseline were Herpes simplex (HSV)-2 (16.1% by serology) and rectal Chlamydia trachomatis (CT) (10.1% by NAAT). 134 participants were enrolled into Stage 1B. During the 12 week period of follow-up 2 HIV, 5 rectal CT, and 5 rectal Neisseria gonorrhea infections were detected. The majority of adverse events (AEs) were infections (N = 56) or gastrointestinal (N = 46) and were mild (69.6%) or moderate (28.0%). Of the participants who completed Stage 1B, 24 were enrolled into Stage 2 and randomized (1:1) to receive TFV or placebo gel. All participants completed Stage 2. The majority of AEs were gastrointestinal (N = 10) and of mild (87.2%) or moderate (10.3%) severity.ConclusionsIn this study we were able to enroll a sexually active population of young MSM and TGW who were willing to use rectal microbicides. TFV gel was safe and acceptable and should be further developed as an alternative HIV prevention intervention for this population.Trial RegistrationClinicalTrials.gov NCT01283360
The purpose of this study was to determine whether the development of a standardized approach to the collection of intestinal tissue from healthy volunteers, isolation of gut associated lymphoid tissue mucosal mononuclear cells (MMC), and characterization of mucosal T cell phenotypes by flow cytometry was sufficient to minimize differences in the normative ranges of flow parameters generated at two trial sites. Forty healthy male study participants were enrolled in Pittsburgh and Los Angeles. MMC were isolated from rectal biopsies using the same biopsy acquisition and enzymatic digestion protocols. As an additional comparator, peripheral blood mononuclear cells (PBMC) were collected from the study participants. For quality control, cryopreserved PBMC from a single donor were supplied to both sites from a central repository (qPBMC). Using a jointly optimized standard operating procedure, cells were isolated from tissue and blood and stained with monoclonal antibodies targeted to T cell phenotypic markers. Site-specific flow data were analyzed by an independent center which analyzed all data from both sites. Ranges for frequencies for overall CD4+ and CD8+ T cells, derived from the qPBMC samples, were equivalent at both UCLA and MWRI. However, there were significant differences across sites for the majority of T cell activation and memory subsets in qPBMC as well as PBMC and MMC. Standardized protocols to collect, stain, and analyze MMC and PBMC, including centralized analysis, can reduce but not exclude variability in reporting flow data within multi-site studies. Based on these data, centralized processing, flow cytometry, and analysis of samples may provide more robust data across multi-site studies. Centralized processing requires either shipping of fresh samples or cryopreservation and the decision to perform centralized versus site processing needs to take into account the drawbacks and restrictions associated with each method.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.