[Purpose] This study determined whether the results of the mobility assessment of pelvic
and thoracic rotation (static evaluation), which is often used in clinical settings, are
related to step length asymmetry. Moreover, we identified the postural evaluation of
rotation that may be related to gait asymmetry. [Participants and Methods] We hypothesize
that a certain relationship exists between the static assessments of pelvic rotation and
step length asymmetry. Fifteen healthy adult males participated in static posture and gait
motion analyses using a motion-capture system. The static evaluation was analyzed using
three parameters: pelvic rotation in standing, pelvic rotation with kneeling, and thorax
rotation in sitting. [Results] The relationship between the asymmetric variables obtained
from static evaluation and gait observations demonstrated a significant correlation. The
asymmetric variables of step length and asymmetric variables of thorax rotation in sitting
showed a significant relationship. Furthermore, significant correlations were found
between asymmetric variables of pelvic rotation during gait and asymmetric variables of
step length and between asymmetric variables of pelvic rotation during gait and asymmetric
variables of thorax rotation in sitting. [Conclusion] This study revealed asymmetric
relationships between thorax rotation in sitting test and step length asymmetry in the
gait. Asymmetry in the thorax rotation in sitting may be caused by a gait with biased
pelvic rotation.
The purpose of this study was to clarify the relationships between the chest and abdominal circumferences, and the thickness of the transversus abdominis during breathing. [Participants and Methods] The participants were 11 healthy adult females. The chest circumference, the abdominal circumference, and the thickness of the transversus abdominis during respiratory exercise were measured with the elastic strain sensor C-STRETCH and an ultrasonic diagnostic device. [Results] The amount of change in the chest circumference did not correlate with the difference in the thickness of the transversus abdominis. However, the amount of change in the abdominal circumference was significantly positively correlated with the change in the thickness of the transversus abdominis.[Conclusion] This study showed that abdominal circumference could be used to infer the muscle thickness of the transversus abdominis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.