High-resolution arrays of discrete monocrystalline scintillators used for gamma photon coincidence detection in pet are costly and complex to fabricate, and exhibit intrinsically non-uniform sensitivity with respect to emission angle. nanocomposites and transparent ceramics are two alternative classes of scintillator materials which can be formed into large monolithic structures, and which, when coupled to optical photodetector arrays, may offer a pathway to low cost, high-sensitivity, high-resolution pet. However, due to their high optical attenuation and scattering relative to monocrystalline scintillators, these materials exhibit an inherent trade-off between detection sensitivity and the number of scintillation photons which reach the optical photodetectors. in this work, a method for optimising scintillator thickness to maximise the probability of locating the point of interaction of 511 keV photons in a monolithic scintillator within a specified error bound is proposed and evaluated for five nanocomposite materials (LaBr 3 :ce-polystyrene, Gd 2 o 3-polyvinyl toluene, LaF 3 :ce-polystyrene, LaF 3 :Ce-oleic acid and YAG:Ce-polystyrene) and four ceramics (GAGG:Ce, GLuGAG:Ce, GYGAG:Ce and LuAG:Pr). LaF 3 :Ce-polystyrene and GLuGAG:Ce were the best-performing nanocomposite and ceramic materials, respectively, with maximum sensitivities of 48.8% and 67.8% for 5 mm localisation accuracy with scintillator thicknesses of 42.6 mm and 27.5 mm, respectively. Detection of high-energy photons for positron emission tomography (PET) is inherently challenging due to their highly penetrating nature. Solid-state detectors are unable to directly detect such photons with high efficiency, due to the limited detector thickness (typically <1 mm) and low density and effective atomic number of most semiconductors 1,2. To increase sensitivity to high energy photons, in most applications it is necessary to optically couple a photodetector to a scintillator. When a high-energy photon deposits energy in the scintillator, the energy is absorbed by dopant atoms (commonly cerium, europium or thallium) and re-radiated as multiple lower-energy photons-typically in the optical range-which can be detected by a solid-state photodetector or photomultiplier tube 3. Many excellent scintillator materials are now available, including some with good sensitivity to high energy photons due to their high density and effective atomic number 3,4. The best of these also provide high light output, good energy resolution and fast decay time, and scintillate at wavelengths which are compatible with semiconductor photodetectors 3-5. Conventionally, high spatial resolution PET requires the use of a large number of very small, discrete, optically isolated scintillator crystals, either individually coupled to a photodetector cell or multiplexed via some sort of light-sharing scheme. High gamma photon sensitivity requires a large radial scintillator thickness, while maintaining a uniformly high spatial resolution across the field of view requires very narrow cryst...
This paper presents a simulation study of BrachyShade, a proposed internal source-tracking system for real time quality assurance in high dose rate prostate brachytherapy. BrachyShade consists of a set of spherical tungsten occluders located above a pixellated silicon photodetector. The source location is estimated by minimising the mean squared error between a parametric model of the shadow image and acquired images of the shadows projected on the detector plane. A novel algorithm is finally employed to correct the systemic error resulting from Compton scattering in the medium. The worst-case error obtained with BrachyShade for a 13.5 ms image acquisition is less than 1.3 mm in the most distant part of the treatment volume, while for 75% of source locations an error of less than 0.42 mm was achieved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.