DWI has the potential in clinical appreciation to detect malignant breast tumors and support the evaluation of tumor extension. However, the benign proliferative change remains to be studied as it mimics the malignant phenomenon on the ADC map.
The authors used breast diffusion-weighted imaging (DWI) to diagnose breast cancer and identify cancer extension. Isotropic DWI was performed with EPI. The apparent diffusion coefficient (ADC) value was calculated and displayed on an ADC map. The authors compared between the distribution of low ADC values and pathologic cancer extension. The mean ADC value of breast cancer was 1.12 +/- 0.24 x 10(-3) mm/s, which was lower than that of normal breast tissue. The ADC value for invasive ductal carcinoma was lower than that of noninvasive ductal carcinoma. The sensitivity of the ADC value for breast cancer using a threshold of less than 1.6 x 10(-3) mm/s was 95%. Seventy-five percent of all cases showed precise distribution of low ADC value as cancer extension. The causes of underestimation were susceptibility artifact from bleeding and the limit of spatial resolution. Benign proliferative change showed a low ADC value. The authors conclude that DWI has a potential for clinical appreciation in detecting breast cancer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.