This study was conducted to assess the ability of two-dimensional tissue tracking (2DTT) to evaluate changes in left ventricular (LV) myocardial function associated with sustained high electrical pacing. Pacemakers were implanted at the right ventricular (RV) apex of five female Beagles, and sustained high electrical pacing of 250 beats per minute (bpm) was performed for three consecutive weeks. Conventional echocardiography and 2DTT were performed at baseline, and at every week for three weeks with pacing. The baseline parameters were then compared to those of weeks 1, 2, and 3. Three weeks of pacing resulted in significant reduction of radial and circumferential global strains (p < 0.001). Regional analysis revealed reduction of segmental strains in both radial and circumferential directions, as well as increased dyssynchrony after three weeks of pacing in the radial direction (p = 0.0007). The results of this study revealed the ability of 2DTT to measure radial and circumferential strains in dogs with sustained high-electrical pacing, and allowed assessment of global and regional myocardial function and the degree of dyssynchrony.
Abstract. Pimobendan and SCH00013 are calcium sensitizers that possess dual action of calcium sensitization and phosphodiesterase-III inhibition. This study was conducted to comparatively evaluate the effect of these medications on the myocardial function of the canine pacing-induced heart failure model using echocardiography. Heart failure was induced in 20 dogs, to which pimobendan and two different doses of SCH00013 were administered orally to 15 dogs for 3 weeks, and the remaining 5 dogs served as the control. Cardiac evaluations were performed at baseline, week 1, week 2, and week 3. Significant thinning and dilation of the left ventricles, with systolic dysfunction, indicated by reduction of fractional shortening (FS) and strain values, were observed with a low dose of SCH00013. Whereas, although systolic dysfunction was observed with reduction of FS and radial strain, significant dilation and thinning of the left ventricles and reduction of circumferential strain were not observed with pimobendan. Pimobendan had a potent positive inotropic effect, with little effect on synchronicity, while low-dose SCH00013 had a weaker positive inotropic effect but was able to sustain synchronicity. Although, it failed to show significant statistical differences, the results of this study allow speculations that administration of pimobendan and SCH00013 may have differing effect on the myocardial function in the canine pacing-induced heart failure model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.