Peripheral nerve disconnections cause severe muscle atrophy and consequently, paralysis of limbs. Reinnervation of denervated muscle by transplanting motor neurons and applying Functional Electrical Stimulation (FES) onto peripheral nerves is an important procedure for preventing irreversible degeneration of muscle tissues. After the reinnervation of denervated muscles, multiple peripheral nerves should be stimulated independently to control joint motion and reconstruct functional movements of limbs by the FES. In this study, a wirelessly powered two-channel neurostimulator was developed with the purpose of applying selective FES to two peripheral nerves—the peroneal nerve and the tibial nerve in a rat. The neurostimulator was designed in such a way that power could be supplied wirelessly, from a transmitter coil to a receiver coil. The receiver coil was connected, in turn, to the peroneal and tibial nerves in the rat. The receiver circuit had a low pass filter to allow detection of the frequency of the transmitter signal. The stimulation of the nerves was switched according to the frequency of the transmitter signal. Dorsal/plantar flexion of the rat ankle joint was selectively induced by the developed neurostimulator. The rat ankle joint angle was controlled by changing the stimulation electrode and the stimulation current, based on the Proportional Integral (PI) control method using a visual feedback control system. This study was aimed at controlling the leg motion by stimulating the peripheral nerves using the neurostimulator.
A wirelessly powered four-channel neurostimulator was developed for applying selective Functional Electrical Stimulation (FES) to four peripheral nerves to control the ankle and knee joints of a rat. The power of the neurostimulator was wirelessly supplied from a transmitter device, and the four nerves were connected to the receiver device, which controlled the ankle and knee joints in the rat. The receiver device had functions to detect the frequency of the transmitter signal from the transmitter coil. The stimulation site of the nerves was selected according to the frequency of the transmitter signal. The rat toe position was controlled by changing the angles of the ankle and knee joints. The joint angles were controlled by the stimulation current applied to each nerve independently. The stimulation currents were adjusted by the Proportional Integral Differential (PID) and feed-forward control method through a visual feedback control system, and the walking trajectory of a rat’s hind leg was reconstructed. This study contributes to controlling the multiple joints of a leg and reconstructing functional motions such as walking using the robotic control technology.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.