Background The application of whole-exome sequencing for the diagnosis of genetic disease has paved the way for systems-based approaches in the clinical laboratory. Here, we describe a clinical metabolomics method for the screening of metabolic diseases through the analysis of a multi-pronged mass spectrometry platform. By simultaneously measuring hundreds of metabolites in a single sample, clinical metabolomics offers a comprehensive approach to identify metabolic perturbations across multiple biochemical pathways. Methods We conducted a single- and multi-day precision study on hundreds of metabolites in human plasma on 4, multi-arm, high-throughput metabolomics platforms. Results The average laboratory coefficient of variation (CV) on the 4 platforms was between 9.3 and 11.5% (median, 6.5–8.4%), average inter-assay CV on the 4 platforms ranged from 9.9 to 12.6% (median, 7.0–8.3%) and average intra-assay CV on the 4 platforms ranged from 5.7 to 6.9% (median, 3.5–4.4%). In relation to patient sample testing, the precision of multiple biomarkers associated with IEM disorders showed CVs that ranged from 0.2 to 11.0% across 4 analytical batches. Conclusions This evaluation describes single and multi-day precision across 4 identical metabolomics platforms, comprised each of 4 independent method arms, and reproducibility of the method for the measurement of key IEM metabolites in patient samples across multiple analytical batches, providing evidence that the method is robust and reproducible for the screening of patients with inborn errors of metabolism.
Multimetabolite panels can enable accurate GFR estimation. Metabolomic equations, preferably excluding creatinine and demographic characteristics, should be tested for robustness and generalizability as a potential confirmatory test when eGFRcr is unreliable.
Rice bran contains essential nutrients, antioxidants, and bioactives with anti-inflammatory and diarrheal protective properties important for infants. This 6-month randomized controlled trial investigated the effects of heat-stabilized rice bran supplementation during Malian infant weaning. Fifty healthy 6-month-old infants were randomized to a rice bran intervention (N = 25) or non-intervention control group (N = 25). Intervention infants received dose-escalating rice bran supplementation for 6 months (1–5 g/day). Monthly infant dried blood spot and anthropometric measurements were collected. Dried blood spot metabolite abundances were compared monthly according to diet for six months. Supplementation resulted in favorable weight-for-age and weight-for-length z-score changes. Non-targeted dried blood spot-based metabolomics identified 796 metabolites, of which 33% had significant fold differences between groups (7–12 months). Lipids and amino acids represented 70.6% of the metabolites identified. Rice bran supplementation during infant weaning significantly modulated the metabolites involved in antioxidant defenses and with neuroactive properties including reduced glutathione, glycine, glutamate, cysteinylglycine, tryptophan betaine, and choline. These findings support rice bran as a weaning ingredient to meet infant nutritional requirements and with the potential to reduce oxidative stress and improve cognitive outcomes. This study provides evidence for dried blood spots as a cost-effective tool to detect infant biomarkers of nutritional and metabolic status.
BACKGROUND: Clinical practice guidelines recommend estimation of glomerular filtration rate (eGFR) using validated equations based on serum creatinine (eGFRcr), cystatin C (eGFRcys), or both (eGFRcr-cys). However, when compared with the measured GFR (mGFR), only eGFRcr-cys meets recommended performance standards. Our goal was to develop a more accurate eGFR method using a panel of metabolites without creatinine, cystatin C, or demographic variables. METHODS: An ultra-performance liquid chromatography-tandem mass spectrometry assay for acetylthreonine, phenylacetylglutamine, pseudouridine, and tryptophan was developed, and a 20-day, multiinstrument analytical validation was conducted. The assay was tested in 2424 participants with mGFR data from 4 independent research studies. A new GFR equation (eGFRmet) was developed in a random subset (n = 1615) and evaluated in the remaining participants (n = 809). Performance was assessed as the frequency of large errors [estimates that differed from mGFR by at least 30% (1 — P30); goal <10%]. RESULTS: The assay had a mean imprecision (≤10% intraassay, ≤6.9% interassay), linearity over the quantitative range (r2 > 0.98), and analyte recovery (98.5%– 113%). There was no carryover, no interferences observed, and analyte stability was established. In addition, 1 — P30 in the validation set for eGFRmet (10.0%) was more accurate than eGFRcr (13.1%) and eGFRcys (12.0%) but not eGFRcr-cys (8.7%). Combining metabolites, creatinine, cystatin C, and demographics led to the most accurate equation (7.0%). Neither equation had substantial variation among population subgroups. CONCLUSIONS: The new eGFRmet equation could serve as a confirmatory test for GFR estimation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.