This study evaluated the cytotoxic effect and the ability to inhibit matrix metalloproteinases (MMP-2 and MMP-9) of 0.2% chitosan (CH) and 1% acetic acid (AA) compared with 17% ethylenediaminetetraacetic acid (EDTA). Cell viability assay was performed according to ISO 10993-5 with mouse fibroblasts (L929). The culture was exposed to 0.2% CH, 1% AA, and 17% EDTA. The chelating agents were evaluated immediately after contact with the cells and after 6 h, 12 h, and 24 h of incubation. Cell viability was analyzed using the 3-(4,5-dimethythiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay. Inhibition of the gelatinolytic activity of MMP-2 and MMP-9 was evaluated by gelatin zymography. Different concentrations of CH were evaluated: 50 mM, 5 mM, 0.5 mM, and 0.05 mM. EDTA (0.5 mM) was used as a positive control. The results demonstrated that CH and AA had an initial cytotoxic effect, which decreased after 6 h, 12 h, and 24 h, being statistically similar to EDTA (P > 0.05). Additionally, CH at concentrations of 50 mM, 5 mM, and 0.5 mM had an inhibitory effect on MMP-2 and MMP-9, similar to that of the control with EDTA. The chelating agents had no cytotoxic effects after 24 h. MMP-2 and MMP-9 were inhibited by the experimental solutions.
Aim: To evaluate the effectiveness of different endodontic irrigants against Enterococcus faecalis (ATCC 29212).Methods: Seventy bovine mandibular incisors were prepared, inoculated with a bacterial strain for 60 days and divided into the following groups: positive control; negative control; 2.5% NaOCl; 17% EDTA; 0.2% chitosan; 2.5% NaOCl + 0.2% chitosan; and 2.5% NaOCl + 17% EDTA. The irrigation protocol was performed using an experimental peristaltic pump device, with the irrigating solutions circulating within the apparatus at a constant flow for 10 min. Paper-point samples were then collected from the root canals and immersed in 7 mL of brain heart infusion broth, followed by incubation at 37°C for 48 h. Bacterial growth was assessed by turbidity of the culture medium.Results: E. faecalis was present in all samples after the use of different irrigants.Conclusion: The different irrigants tested were not effective in completely eliminating dentin bacterial contamination with E. faecalis.
Objective The aim of the present study was to characterize a novel resin-based monoblock endodontic obturation system consisting of a polymeric cone and a resin-based endodontic sealer. Methods The preliminary tests performed for the experimental cone were as follows: cohesive strength, dimensional stability, standardization of the diameter and taper, calcium ion release, and radiopacity, for the characterization of the experimental sealer, film thickness and flow tests were performed. Tests were performed according to the American National Standards Institute/American Dental Association (ANSI/ADA) Standards Nos. 57 and 78. The experimental cone was compared to gutta-percha, whereas the experimental sealer was compared to AH Plus. Data were analyzed by Student's t-test (α = 0.05). Results The experimental cone had superior values for cohesive strength and dimensional stability compared to gutta-percha. Regarding calcium ion release, the experimental system continued to release calcium ions after 30 days. Film thickness was similar for both endodontic sealers; conversely, the experimental resin-based sealer achieved higher values for flow compared to AH Plus. Conclusion The experimental resin-based monoblock obturation system fully met the requirements of the ANSI/ADA Standard No. 78 and the ANSI/ADA Standard No. 57, except for radiopacity. Considering this, further studies are still needed to evaluate other radiopacifiers and the effect of their incorporation on the physicochemical properties of this novel resin-based monoblock endodontic obturation system.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.