PurposeWe report a case of retrocorneal fibrous membrane (RCFM) formation following penetrating keratoplasty (PK) and intraoperative optical coherence tomography (OCT)-guided excision of this membrane.ObservationsA 68-year-old woman with primary open angle glaucoma and corneal decompensation of the right eye secondary to tube shunt presented for 3-month follow-up of PK. On examination of the right eye, the patient was noted to have a glassy pupillary membrane with traction on the iris. Anterior segment OCT confirmed a membrane connecting the iris to host cornea. The patient underwent biopsy and excision of the membrane assisted by intraoperative OCT. Pathological examination was consistent with Descemet's membrane proliferation. We suspect that this membrane represents retained host's Descemet's membrane following corneal transplantation.ConclusionsThis case highlights the existence of RCFM formation in the context of retained host cornea following PK and the role of intraoperative OCT in management.
Purpose: The purpose of this study was to compare the accuracy of 2 portable tonometers, Tonopen and iCare, in extreme corneal edema, while also accounting for the location of pressure measurement over a wide range of intraocular pressure (IOP). Methods: Utilizing an experimental laboratory investigation, IOP measurements were obtained with iCare and Tonopen against an internal digital manometer in 2 enucleated human cadaveric eyes with edematous corneas. Pachymetry was used to measure central corneal thickness in each eye. Each eye was then mounted on an upright-positioned mannequin, and a 30-G needle connected to a digital manometer was introduced into the anterior chamber at the limbus. Pressures were maintained at 0, 10, 20, 30, 40, and 50 mmHg using the digital manometer. Three measurements were taken with the tonometers at the central cornea, limbal cornea, and sclera, for a total of 9 measurements per device per eye at each manometric pressure reading. Results: Comparing the mean absolute error of Tonopen versus iCare measurements at the central cornea for each manometric pressure reading, both devices underestimated the control at pressures >10 mmHg, with mean error increasing as IOP increased [mean absolute error (MAE) ranged from 1.67 to 13.33 with Tonopen and 3.67 to 21.00 with iCare]. Tonopen more accurately estimated pressure with an average MAE of 5.72 at the central cornea, compared with MAE of 10.83 at the central cornea for iCare (P<0.03). Comparing MAE between the devices at the limbus, there was no significant difference between the 2 (P=0.91), with average MAE for the Tonopen 5.47 and average MAE for the iCare 5.22. There was no significant difference between average MAE for Tonopen measurements at the central cornea versus the limbus (P=0.89), while the iCare was more accurate at the limbus with average MAE of 5.22 than the central cornea with average MAE of 10.83 (P<0.03). When measuring at the sclera, there was no statistically significant difference between average MAE for Tonopen (18.03) versus iCare (10.39) (P=0.24). Discussion: Tonopen was more accurate than iCare when measuring at the central cornea, but consistently underestimated the control. MAE for both devices increased linearly with increasing true IOP. With limbus measurements in an edematous cornea, Tonopen and iCare performed similarly. The iCare performed better at the limbus than at the central cornea. Scleral measurements for both Tonopen and iCare were poor. In this experimental model, Tonopen performed superiorly to iCare with central cornea measurements in a grossly edematous cornea. Both devices underestimated true IOP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.