Background Testicular torsion is a surgical emergency, and time to detorsion is imperative for testicular salvage. During the COVID-19 pandemic, patients may delay emergency care due to stay-at-home orders and concern of COVID-19 exposure. Objective To assess whether emergency presentation for testicular torsion was delayed during the COVID-19 pandemic, and whether the rate of orchiectomy increased compared to a retrospective period. Study Design Patients were prospectively enrolled in a multicenter study from seven institutions in the United States and Canada. Inclusion criteria were patients two months to 18 years of age with acute testicular torsion from March through July 2020. The retrospective group included patients from January 2019 through February 2020. Statistical analysis was performed using Kruskal-Wallis tests, Chi-square tests, and logistic regression. Results A total of 221 patients were included: 84 patients in the COVID-19 cohort and 137 in the retrospective cohort. Median times from symptom onset to emergency department presentation during COVID-19 compared to the retrospective period were 17.9 hours (IQR 5.5-48.0) and 7.5 hours (IQR 4.0-28.0) respectively (p = 0.04). In the COVID-19 cohort, 42% of patients underwent orchiectomy compared to 29% of pre-pandemic controls (p = 0.06). During COVID-19, 46% patients endorsed delay in presentation compared to 33% in the retrospective group (p = 0.04). Discussion We found a significantly longer time from testicular torsion symptom onset to presentation during the pandemic and a higher proportion of patients reported delaying care. Strengths of the study include the number of included patients and the multicenter prospective design during the pandemic. Limitations include a retrospective pre-pandemic comparison group. Conclusions In a large multicenter study we found a significantly longer time from testicular torsion symptom onset to presentation during the pandemic and a significantly higher proportion of patients reported delaying care. Based on the findings of this study, more patient education is needed on the management of testicular torsion during a pandemic.
Of men undergoing prostate biopsy using a modern extended biopsy scheme obese men were younger, had a larger prostate and were less likely to have abnormal digital rectal examinations. Although some trends toward a lower detection rate in obese men were observed, such differences were not observed on multivariate analysis, nor were any differences observed in the incidence of higher grade tumors, thus questioning the effect of obesity on prostate cancer detection and behavior in our cases series.
Introduction Currently, the surgical treatment of infected penile prostheses is complete removal and either immediate salvage procedure, which carries a significant infection risk, or delayed implantation. With delayed implantation the risk of infection is lower, but the patient loses penile length and width due to corporal fibrosis. Aim We present our experience with the use of a novel temporary synthetic high purity calcium sulfate (SHPCaSO4) component that acts as a “spacer” at the time of removal of an infected prosthesis while providing constant delivery of local antibiotic elution to the infected area. Main Outcome Measures Demonstrate that the use of a novel material, SHPCaSO4, can be an innovative way to bridge the gap between removal of an infected penile implant and delayed reimplantation. Methods Two patients (Patient A and B) presented with pain and erythema and were found to have infected malleable penile prosthesis. Both underwent removal of all infected components, and sent for tissue culture. The SHPCaSO4 was mixed with vancomycin and tobramycin, allowed to set up for 5 minutes, and then injected into the corporal space followed by closure with 2-0 Vicryl sutures. The injected SHPCaSO4 was palpable in the penile shaft both proximally and distally, as an “intracorporal casts.” Results Patients denied pain postoperatively. Delayed implantation occurred at 6 weeks for patient A. This went uneventful and a new three-piece inflatable implant was inserted. Patient B underwent salvage placement of right malleable implant at 15 weeks, and here significant corporal fibrosis was encountered. Patients have had no infection since their delayed implantation (mean follow-up 4 months). Conclusions Data in reference to SHPCaSO4 shows that this product dissolves in approximately 4–6 weeks. This may account for the difference in the ease of delayed implantation between the two patients. Further investigation is warranted.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.