Head-twitch behavior (HTR) is the behavioral signature of psychedelic drugs upon stimulation of the serotonin 5-HT2A receptor (5-HT2AR) in rodents. Following the previous report of a semi-automated detection of HTR based on the dynamics of mouse’s head movement, here we present a system for the identification of individual HTR events in a fully automated fashion. The validity of this fully automated HTR detection system was tested with the psychedelic drug DOI in 5-HT2AR-KO mice, and via evaluation of potential sources of false-positive and false-negative HTR events. The increased throughput in data processing achieved via automation afforded the possibility of conducting otherwise time consuming HTR time-course studies. To further assess the versatility of our system, we also explored the pharmacological interactions between 5-HT2AR and the metabotropic glutamate receptor 2 (mGluR2). Our data demonstrate the potentiation effect of the mGluR2/3 antagonist LY341495 on DOI-induced HTR, as well as the HTR-blocking effect of the mGluR2/3 agonist and antipsychotic drug in development LY404039. This fully automated system can contribute to speed up our understanding of 5-HT2AR’s pharmacology and its characteristic behavioral outputs in rodents.
Several pharmacophore models have been proposed for 5-HT2A serotonin receptor antagonists. These typically consist of two aromatic/hydrophobic moieties separated by a given distance from each other, and from a basic amine. Although specified distances might vary, the models are relatively similar in their general construction. Because our preliminary data indicated that two aromatic (hydrophobic) moieties might not be required for such action, we deconstructed the serotonin-dopamine antipsychotic agent risperidone (1) into four smaller structural fragments that were thoroughly examined in 5-HT2A receptor binding and functional (i.e., two-electrode voltage clamp – TEVC – and intracellular calcium release) assays. It was apparent that truncated risperidone analogs behaved as antagonists. In particular, 6-fluoro-3-(1-methylpiperidin-4-yl)benzisoxazole (4) displayed high affinity for 5-HT2A receptors (Ki ca 12 nM) relative to risperidone (Ki ca 5 nM) and behaved as a potent 5-HT2A serotonin receptor antagonist. These results suggest that multiple aromatic (hydrophobic) moieties are not essential for high-affinity 5-HT2A receptor binding and antagonist activity and that current pharmacophore models for such agents are very much in need of revision.
These findings further support the existence of a functionally relevant crosstalk between 5-HT and mGlu2 receptors in different preclinical models of antipsychotic activity.
Introduction Optimal paediatric femoral shaft fracture patterns or lengths amenable to titanium elastic nail stabilization have not been well defined. The purpose of this study is to identify radiographic parameters predictive of treatment failure with flexible intramedullary nails based upon fracture morphology. Methods A retrospective review was performed of all femoral shaft fractures treated with flexible intramedullary nails over a five-year period. All patients with at least six weeks of postoperative radiographic imaging were included. Fracture characteristics included location, pattern, length, obliquity, angulation, translation and shortening. Postoperative radiographs were reviewed to determine shortening and angulation. Results There were 58 patients with 60 femoral shaft fractures stabilized with titanium nails, with 46 healing within acceptable parameters and 14 considered malunions. Six of the 14 malunions developed complications requiring early unplanned intervention. No patients in the treatment success group had a complication. Between the treatment success and failure groups, fracture pattern, location, length, obliquity, angulation, translation or shortening were not statistically different. Mean nail canal fill was significantly lower in the failure group (0.72 versus 0.81; p = 0.0146), with a receiver operating characteristic curve identifying canal fill 76% as the optimal threshold. Conclusion This is the first study to measure the length and obliquity of paediatric femoral shaft fractures and to determine their relationship to radiographic alignment after healing. None of the preoperative fracture characteristics were predictive of malalignment or shortening. We recommend the use of larger nail sizes in the treatment of paediatric femoral shaft fractures, especially if there is concern for residual instability. Level of evidence IV
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.