We evaluated the effect of low-intensity pulsed ultrasound stimulation (LIPUS) on the remodelling of callus in a rabbit gap-healing model by bone morphometric analyses using three-dimensional quantitative micro-CT. A tibial osteotomy with a 2 mm gap was immobilised by rigid external fixation and LIPUS was applied using active translucent devices. A control group had sham inactive transducers applied. A region of interest of micro-CT was set at the centre of the osteotomy gap with a width of 1 mm. The morphometric parameters used for evaluation were the volume of mineralised callus (BV) and the volumetric bone mineral density of mineralised tissue (mBMD). The whole region of interest was measured and subdivided into three zones as follows: the periosteal callus zone (external), the medullary callus zone (endosteal) and the cortical gap zone (intercortical). The BV and mBMD were measured for each zone. In the endosteal area, there was a significant increase in the density of newly formed callus which was subsequently diminished by bone resorption that overwhelmed bone formation in this area as the intramedullary canal was restored. In the intercortical area, LIPUS was considered to enhance bone formation throughout the period of observation. These findings indicate that LIPUS could shorten the time required for remodelling and enhance the mineralisation of callus.
For femoral fracture reduction, we have developed a surgical robotic system. Indirect traction is employed in our system. Indirect traction in fracture reduction is a generally used surgical method for preventing complications such as bone splits caused by high stress on bones. For traction, a patient's foot is gripped by a jig and pulled to the distal side. Indirect traction has the advantage of distributing bone stress by utilizing a strong traction force; however, this procedure does not accurately control the proper positioning of fractured fragments when a surgical robot is used. The human leg has knee and an ankle joints, and thus robotic motion presents problems in not being able to directly propagate reduction motion to a fractured femoral fragment, rendering control of bone position difficult. We propose two control methods for fracture reduction robots using external force/torque measurements of the human leg. First proposed method is using a transform function which transform from a force/torque space to a position space. Second is using a simple ligament model. Results showed that the first proposed method reduced repositioning error from 6.8 mm and 15.9 degrees to 0.7 mm and 5.3 degrees and second reduced from 2.1 mm to 0.9 mm.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.