Quasi-static bending and fatigue tests of single-crystal silicon microelements fabricated by photoetching were performed. The microelements were subjected to simple bending and three-point bending with two-support roll length of 1.5 mm. The tests were conducted by using a specially designed electromagnetic actuator based testing machine (load range: 0.1 mN-5 N, accuracy: 0.02 mN), which enables mechanical testing including fatigue of microelements. Mechanical testing including fatigue of microelements could be performed with sufficient precision. Single-crystal silicon microelements deformed elastically until final catastrophic failure, showing a brittle nature. The influence of specimen size on quasi-static fracture behavior was investigated: fracture strength increased with a decrease in sample width, and the maximum fracture strength reached 7.7 GPa. The influence of water on fatigue strength was discussed. The fracture surface and sample surface were examined using an atomic force microscope. Nanoscopic damage during testing was evaluated, and the fracture mechanisms were discussed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.