Numerous methods and devices are available for implant fixation in anterior cruciate ligament (ACL) reconstruction. Biomechanical data indicate high variability in fixation stability across different devices. This study aims to provide a better insight into measuring the structural characteristics and mechanical behavior of ACL implant fixations. Fourteen human tibial specimens with reconstructed ACLs were subjected to progressively increasing dynamic loading until failure. The motions of the tibia, the proximal and distal graft ends, as well as the testing frame and actuator, were continuously recorded via a motion tracking system. Significantly higher displacements of the machine actuator (1.0 mm at graft slippage onset, and 12.2 mm at ultimate load) were measured compared to the displacements of the proximal (0.8 and 4.3 mm, respectively) and distal graft (0.1 and 3.4 mm, respectively) ends. The displacements measured at different sites showed significant correlations. The provided data suggest significant and systematic inaccuracies in the stiffness and slippage of the fixation when using machine displacement, as commonly reported in the literature. The assessment of the distal graft displacement excludes the artifactual graft elongation, and most accurately reflects the graft slippage onset indicating clinical failure. Considering the high displacement at the ultimate load, the ultimate load could be used as a standardized variable to compare different fixation methods. However, the ultimate load alone is not sufficient to qualitatively describe fixation stability.
Background and Objectives: Wound infections provoked by alterations in microcirculation are major complications in the treatment of trochanteric femur fractures. Surgical fracture fixation on a traction table is the gold standard for treatment, but the effect on tissue microcirculation is unknown. Microcirculation could be impaired by the pull on the soft-tissue or by a release of vasoactive factors. We hypothesized that intraoperative traction impairs soft-tissue microcirculation. Materials and Methods: In 22 patients (14 women, eight men), average age 78 years (range 36–96 ± 14), with trochanteric femur fractures, non-invasive laser-Doppler spectrophotometry was used to assess oxygen saturation, hemoglobin content, and blood flow in the skin and subcutaneous tissue before and after application of traction. Measurements were recorded in nine locations around the greater trochanter at a depth of 2, 8, and 15 mm before and after fracture reduction by traction. Results: No differences were found in any depth with traction compared to without (oxygen saturation: p = 0.751, p = 0.308, and p = 0.955, haemoglobin content: p = 0.651, p = 0.928, and p = 0.926, blood flow: p = 0.829, p = 0.866, and p = 0.411). Conclusion: In this pilot study, the application of traction does not affect skin and subcutaneous microcirculation in the surgery of proximal femur fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.