Various operation models of ionic polymer actuators have been reported. In ionic polymer actuators including saturated ionic liquid, we discovered the phenomenon that a liquid exuded from a cathode during the voltage application. We can't explain this phenomenon using the reported operation models so far, because other studies have reported on the movement of the ion, but they have not focused on liquid movement. Here, we investigated the behavior of ionic liquid during the voltage application. We observed not only the liquid movement but also size of the course and the movement properties. From these results, we confirmed that cations and anions of ionic liquid moved to a cathode by the electroosmotic flow and propose this as a new operation model.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.