Background/Aims: Rosemont classification (RC) with endoscopic ultrasonography (EUS) is important for diagnosing chronic pancreatitis (CP) but is based only on subjective judgement. EUS shear wave measurement (EUS-SWM) is a precise modality based on objective judgment, but its usefulness has not been extensively studied yet. This study evaluated the utility of EUS-SWM for diagnosing CP and estimating CP severity by determining the presence of endocrine dysfunction along with diabetes mellitus (DM). Methods: Between June 2018 and December 2018, 52 patients who underwent EUS and EUS-SWM were classified into two groups according to RC: non-CP (indeterminate CP and normal) and CP (consistent and suggestive of CP). The EUS-SWM value by shear wave velocity was evaluated with a median value. The EUS-SWM value was compared with RC and the number of EUS features. The diagnostic accuracy and cutoff value of EUS-SWM for CP and DM and its sensitivity and specificity were calculated. Results: The EUS-SWM value significantly positively correlated with the RC and the number of EUS features. The EUS-SWM values that were consistent and suggestive of CP were significantly higher than that of normal. The area under the receiver operating characteristic (AUROC) curve for the diagnostic accuracy of EUS-SWM for CP was 0.97. The cutoff value of 2.19 had 100% sensitivity and 94% specificity. For endocrine dysfunction in CP, the AUROC was 0.75. The cutoff value of 2.78 had 70% sensitivity and 56% specificity. Conclusions: EUS-SWM provides an objective assessment and can be an alternative diagnostic tool for diagnosing CP. EUS-SWM may also be useful for predicting the presence of endocrine dysfunction.
Background and Aim
Chronic pancreatitis (CP) leads to permanent impairment of exocrine and endocrine functions. The endoscopic ultrasonography (EUS)‐based Rosemont classification plays an important role in diagnosing CP. However, it is based on subjective judgment. In contrast, EUS shear wave measurement (EUS‐SWM) has been established to be a precise method for evaluating tissue hardness. This study aimed to evaluate the utility of EUS‐SWM in diagnosing CP and determining exocrine and endocrine dysfunctions.
Methods
We evaluated 40 patients who underwent EUS‐SWM between January 2019 and January 2020. They were classified into the normal pancreas and early, probable, and definite CP groups following the Japan Pancreatic Society criteria. EUS‐SWM value was compared between the normal pancreas group and the early, probable, and definite CP groups. The relationship between EUS‐SWM value and exocrine/endocrine dysfunctions was also assessed. The cut‐off value of EUS‐SWM for diagnosing CP and exocrine/endocrine dysfunctions was investigated.
Results
The EUS‐SWM value was positively correlated with the Japan Pancreatic Society criteria stages. The probable and definite CP groups had significantly higher EUS‐SWM values than the normal group. The areas under the receiver operating characteristic curve for the diagnostic accuracy of EUS‐SWM for CP, exocrine dysfunction, and endocrine dysfunction were 0.92, 0.78, and 0.63, respectively. The cut‐off values of 1.96, 1.96, and 2.34 for diagnosing CP, exocrine dysfunction, and endocrine dysfunctions had 83%, 90%, and 75% sensitivity, respectively, and 100%, 65%, and 64% specificity, respectively.
Conclusions
Endoscopic ultrasonography shear wave measurement provides objective assessment and can thus be an alternative diagnostic tool for diagnosing CP and exocrine/endocrine dysfunctions.
Background and Aim: Few studies have investigated endoscopic ultrasound-guided fineneedle aspiration with contrast-enhanced harmonic imaging (EUS-FNA-CHI) for diagnosing and adequately sampling pancreatic lesions. This study aimed to investigate the efficacy of EUS-FNA-CHI compared with that of endoscopic ultrasound-guided fine-needle aspiration with fundamental B mode imaging (EUS-FNA-FBI) for diagnosing solid pancreatic lesions. Methods: Consecutive patients with solid pancreatic lesions were enrolled prospectively (UMIN 000024467). Only samples obtained during the first needle pass (EUS-FNA-FBI) and second needle pass (EUS-FNA-CHI) were used to compare the accuracy rate for diagnosing pancreatic lesions and rate of adequate sampling for histological evaluation. In patients with hypo-enhancing lesions on contrast-enhanced harmonic EUS (CH-EUS), subgroup analyses were performed. Patients were classified into those with a heterogeneous area in the whole lesion (whole group), those with a heterogeneous area with a non-enhancing area (non-enhancing group), and those with a heterogeneous area with a homogeneous area (homogeneous group). Results: Ninety-three patients were enrolled. Overall, the rates of adequate sampling and sensitivity were significantly higher with EUS-FNA-CHI than with EUS-FNA-FBI (84.9% vs 68.8%, P = 0.003 and 76.5% vs 58.8%, P = 0.011, respectively). The adequate sampling rate and sensitivity were significantly higher with EUS-FNA-CHI than with EUS-FNA-FBI when the mass was > 15 mm. In the non-enhancing and homogeneous groups, the adequate sampling rate and sensitivity were significantly higher with EUS-FNA-CHI than with EUS-FNA-FBI. Conclusions: CH-EUS enables improved observation of pancreatic lesions and helps identify the target of EUS-FNA among different pathological areas of the lesions particularly of > 15 mm. The usefulness of EUS-FNA-CHI M Itonaga et al.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.