In the previous 3D Cauchy-condition surface (CCS) method analysis to reconstruct the magnetic field profile in the Large Helical Device (LHD), one assumed an impractically large number of magnetic sensors, i.e., 440 field sensors and 126 flux loops. In the singular value decomposition (SVD) process employed in the CCS method, a gap is found in the magnitude of the singular values. The most accurate field results can be obtained if all the singular values smaller than the gap threshold are eliminated, independent of the number of boundary elements on the CCS and the number of sensors as well. With the reduction in the number of boundary elements, the required numbers of field sensors and flux loops are significantly reduced to 110 and 25, respectively, without losing the solution accuracy. They can be further reduced to 58 and 13 respectively if considering the symmetry of the field profile in the LHD. This result suggests the possibility of actual application to the LHD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.