BackgroundPatients having arthroscopic shoulder surgery frequently experience periods of inadvertent hypothermia. This common perioperative problem has been linked to adverse patient outcomes such as myocardial ischaemia, surgical site infection and coagulopathy. International perioperative guidelines recommend patient warming, using a forced air warming device, and the use of warmed intraoperative irrigation solutions for the prevention of hypothermia in at-risk patient groups. This trial will investigate the effect of these interventions on patients’ temperature, thermal comfort, and total recovery time.Method/DesignThe trial will employ a randomised 2 x 2 factorial design. Eligible patients will be stratified by anaesthetist and block randomised into one of four groups: Group one will receive preoperative warming with a forced air warming device; group two will receive warmed intraoperative irrigation solutions; group three will receive both preoperative warming and warmed intraoperative irrigation solutions; and group four will receive neither intervention. Participants in all four groups will receive active intraoperative warming with a forced air warming device. The primary outcome measures are postoperative temperature, thermal comfort, and total recovery time. Primary outcomes will undergo a two-way analysis of variance controlling for covariants such as operating room ambient temperature and volume of intraoperative irrigation solution.DiscussionThis trial is designed to confirm the effectiveness of these interventions at maintaining perioperative normothermia and to evaluate if this translates into improved patient outcomes.Australian New Zealand Clinical Trials Registry numberACTRN12610000591055
Preoperative forced-air warming is one way of preventing inadvertent perioperative hypothermia. There is scant evidence, however, on the best warming method or the acceptability of these methods to patients. This pilot study compared two warming protocols: one that commenced at maximum temperature and was titrated down as requested (A) and one that commenced at near body temperature and was titrated up as tolerated (B). A crossover design was used in which each participant (n=10) received both protocols sequentially. The mean device temperature and length of time spent at maximum settings were greater for protocol A (43°C±0°C vs 41°C±1°C, P=.003; and 60±0 vs 41.5±2.8 minutes, P=.004). There was no difference in thermal comfort scores, participant temperature, or sweating between the two protocols. When asked, participants preferred protocol A to B (70% to 30%). Starting at higher device settings appears the more favorable of the two approaches.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.