Diesel particulate filters (DPFs) are a promising technology to detoxify diesel exhaust. However, the secondary combustion of diesel soot and associated compounds may also induce the formation of new pollutants. Diesel soot is rated as carcinogenic to humans and also acts as a carrier for a variety of genotoxic compounds such as certain polycyclic aromatic hydrocarbons (PAHs) or nitrated PAHs (nitro-PAHs). Furthermore, diesel exhaust contains considerable amounts of nitric oxide (NO), which can be converted to more powerful nitrating species like nitrogen dioxide (NO2), nitric acid (HNO3), and others. This mix of compounds may support nitration reactions in DPFs. Herein we report effects of two cordierite-based, monolithic, wall-flow DPFs on emissions of genotoxic PAHs and nitro-PAHs and compare these findings with those of a reporter gene bioassay sensitive to aryl hydrocarbons (AHs). Soot combustion was either catalyzed with an iron- or a copper/iron-based fuel additive (fuel-borne catalysts). A heavy duty diesel engine, operated according to the 8-stage ISO 8178/4 C1 cycle, was used as test platform. Emissions of all investigated 4- to 6-ring PAHs were reduced by about 40-90%, including those rated as carcinogenic. Emissions of 1- and 2-nitronaphthalene increased by about 20-100%. Among the 3-ring nitro-PAHs, emissions of 3-nitrophenanthrene decreased by about 30%, whereas 9-nitrophenanthrene and 9-nitroanthracene were found only after DPFs. In case of 4-ring nitro-PAHs, emissions of 3-nitrofluoranthene, 1-nitropyrene, and 4-nitropyrene decreased by about 40-60% with DPFs. Total AH-receptor (AHR) agonist concentrations of diesel exhaust were lowered by 80-90%, when using the iron- and copper-based DPFs. The tested PAHs accounted for < 1% of the total AHR-mediated response, indicating that considerable amounts of other aryl hydrocarbons must be present in filtered and unfiltered exhaust. We conclude that both DPFs detoxified diesel exhaust with respect to total aryl hydrocarbons, including the investigated carcinogenic PAHs, but we also noticed a secondary formation of selected nitro-PAHs. Nitration reactions were found to be stereoselective with a preferential substitution of hydrogen atoms at peri-positions. The stereoisomers obtained are related to combustion chemistry, but differ from those formed upon atmospheric nitration of PAHs.
Abstract. For the past two decades, the measurement of nitrous oxide (N2O) isotopocules – isotopically substituted molecules 14N15N16O, 15N14N16O and 14N14N18O of the main isotopic species 14N14N16O – has been a promising technique for understanding N2O production and consumption pathways. The coupling of non-cryogenic and tuneable light sources with different detection schemes, such as direct absorption quantum cascade laser absorption spectroscopy (QCLAS), cavity ring-down spectroscopy (CRDS) and off-axis integrated cavity output spectroscopy (OA-ICOS), has enabled the production of commercially available and field-deployable N2O isotopic analyzers. In contrast to traditional isotope-ratio mass spectrometry (IRMS), these instruments are inherently selective for position-specific 15N substitution and provide real-time data, with minimal or no sample pretreatment, which is highly attractive for process studies. Here, we compared the performance of N2O isotope laser spectrometers with the three most common detection schemes: OA-ICOS (N2OIA-30e-EP, ABB – Los Gatos Research Inc.), CRDS (G5131-i, Picarro Inc.) and QCLAS (dual QCLAS and preconcentration, trace gas extractor (TREX)-mini QCLAS, Aerodyne Research Inc.). For each instrument, the precision, drift and repeatability of N2O mole fraction [N2O] and isotope data were tested. The analyzers were then characterized for their dependence on [N2O], gas matrix composition (O2, Ar) and spectral interferences caused by H2O, CO2, CH4 and CO to develop analyzer-specific correction functions. Subsequently, a simulated two-end-member mixing experiment was used to compare the accuracy and repeatability of corrected and calibrated isotope measurements that could be acquired using the different laser spectrometers. Our results show that N2O isotope laser spectrometer performance is governed by an interplay between instrumental precision, drift, matrix effects and spectral interferences. To retrieve compatible and accurate results, it is necessary to include appropriate reference materials following the identical treatment (IT) principle during every measurement. Remaining differences between sample and reference gas compositions have to be corrected by applying analyzer-specific correction algorithms. These matrix and trace gas correction equations vary considerably according to N2O mole fraction, complicating the procedure further. Thus, researchers should strive to minimize differences in composition between sample and reference gases. In closing, we provide a calibration workflow to guide researchers in the operation of N2O isotope laser spectrometers in order to acquire accurate N2O isotope analyses. We anticipate that this workflow will assist in applications where matrix and trace gas compositions vary considerably (e.g., laboratory incubations, N2O liberated from wastewater or groundwater), as well as extend to future analyzer models and instruments focusing on isotopic species of other molecules.
Diesel exhaust contains several genotoxic compounds that may or may not penetrate diesel particulate filters (DPFs). Furthermore, the DPF-supported combustion of soot and adsorbed compounds may lead to the formation of additional pollutants. Herein, we compare the impact of 14 different DPFs on emissions of known genotoxic compounds. During a four year period, these DPFs were tested on a heavy duty diesel engine, operated in the ISO 8178/4 C1 cycle. Integral samples, including gas-phase and particle-bound matter were taken. All DPFs were efficient wall-flow filters with solid particulate number filtration efficiencies eta > 98%. On the basis of their CO, NO, and NO(2) emission characteristics, two different filter families were distinguished. DPFs with high oxidation potential (hox, n = 8) converted CO and NO besides hydrocarbons, whereas low oxidation potential DPFs (lox, n = 6) did not support CO and NO oxidation but still converted hydrocarbons. Lox-DPFs reduced NO(2) from 1.0 +/- 0.3 (engine-out) to 0.42 +/- 0.11 g/kWh (eta = 0.59), whereas hox-DPFs induced a NO(2) formation up to 3.3 +/- 0.7 g/kWh (eta = -2.16). Emissions of genotoxic PAHs decreased for both filter families. Conversion efficiencies varied for individual PAHs and were lower for lox- (eta = 0.31-0.87) than for hox-DPFs (eta = 0.75-0.98). Certain nitro-PAHs were formed indicating that nitration is an important step along PAH oxidation. For example, 1-nitronaphthalene emissions increased from 11 to 17 to 21 microg/L without, with lox-, and hox-DPFs respectively, whereas 2-nitronaphthalene emissions decreased from 25 to 19 to 4.7 microg/L. In contrast to our expectations, the nitration potential of lox-DPFs was higher than the one of hox-DPFs, despite the intense NO(2) formation of the latter. The filters converted most genotoxic PAHs and nitro-PAHs and most soot particles, acting as carriers for these compounds. Hox-DPF exhaust remains oxidizing and therefore is expected to support atmospheric oxidation reactions, whereas lox-DPF exhaust is reducing and consuming oxidants such as ozone, when mixed with ambient air.
Potential risks of a secondary formation of polychlorinated dibenzodioxins/furans (PCDD/Fs) were assessed for two cordierite-based, wall-through diesel particulate filters (DPFs) for which soot combustion was either catalyzed with an iron- or a copper-based fuel additive. A heavy duty diesel engine was used as test platform, applying the eight-stage ISO 8178/4 C1 cycle. DPF applications neither affected the engine performance, nor did they increase NO, NO2, CO, and CO2 emissions. The latter is a metric for fuel consumption. THC emissions decreased by about 40% when deploying DPFs. PCDD/F emissions, with a focus on tetra- to octachlorinated congeners, were compared under standard and worst case conditions (enhanced chlorine uptake). The iron-catalyzed DPF neither increased PCDD/F emissions, nor did it change the congener pattern, even when traces of chlorine became available. In case of copper, PCDD/F emissions increased by up to 3 orders of magnitude from 22 to 200 to 12 700 pg I-TEQ/L with fuels of < 2, 14, and 110 microg/g chlorine, respectively. Mainly lower chlorinated DD/Fs were formed. Based on these substantial effects on PCDD/F emissions, the copper-catalyzed DPF system was not approved for workplace applications, whereas the iron system fulfilled all the specifications of the Swiss procedures for DPF approval (VERT).
Abstract. Nitrous oxide fluxes were measured at the Lägeren CarboEurope IP flux site over the multi-species mixed forest dominated by European beech and Norway spruce. Measurements were carried out during a four-week period in October-November 2005 during leaf senescence. Fluxes were measured with a standard ultrasonic anemometer in combination with a quantum cascade laser absorption spectrometer that measured N 2 O, CO 2 , and H 2 O mixing ratios simultaneously at 5 Hz time resolution. To distinguish insignificant fluxes from significant ones it is proposed to use a new approach based on the significance of the correlation coefficient between vertical wind speed and mixing ratio fluctuations. This procedure eliminated roughly 56% of our half-hourly fluxes. Based on the remaining, quality checked N 2 O fluxes we quantified the mean efflux at 0.8±0.4 µmol m −2 h −1 (mean ± standard error). Most of the contribution to the N 2 O flux occurred during a 6.5-h period starting 4.5 h before each precipitation event. No relation with precipitation amount could be found. Visibility data representing fog density and duration at the site indicate that wetting of the canopy may have as strong an effect on N 2 O effluxes as does below-ground microbial activity. It is speculated that above-ground N 2 O production from the senescing leaves at high moisture (fog, drizzle, onset of precipitation event) may be responsible for part of the measured flux.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.