Despite often minute concentrations in vivo, D-amino acid containing peptides (DAACPs) are crucial to many life processes. Standard proteomics protocols fail to detect them as D/L substitutions do not affect the peptide parent and fragment masses. The differences in fragment yields are often limited, obstructing the investigations of important but low abundance epimers in isomeric mixtures. Separation of D/L-peptides using ion mobility spectrometry (IMS) was impeded by small collision cross section differences (commonly ~1%). Here, broad baseline separation of DAACPs with up to ~30 residues employing trapped IMS with resolving power up to ~340, followed by time-of-flight mass spectrometry is demonstrated. The D/L-pairs co-eluting in one charge state were resolved in another, and epimers merged as protonated species were resolved upon metalation, effectively turning the charge state and cationization mode into extra separation dimensions. Linear quantification down to 0.25% proved the utility of high resolution IMS-MS for real samples with large inter-isomeric dynamic range. Very close relative mobilities found for DAACP pairs using traveling-wave IMS (TWIMS) with different ion sources and faster IMS separations showed the transferability of results across IMS platforms. Fragmentation of epimers can enhance their identification and further improve detection and quantification limits, and we demonstrate the advantages of online mobility separated collision-induced dissociation (CID) followed by high resolution mass spectrometry (TIMS-CID-MS) for epimer analysis.
Lipids are a major class of molecules that play key roles in different biological processes. Understanding their biological roles and mechanisms remains analytically challenging due to their high isomeric content (e.g., varying acyl chain positions and/or double bond locations/geometries) in eukaryotic cells. In the present work, a combination of liquid chromatography (LC) followed by high resolution trapped ion mobility spectrometry−mass spectrometry (TIMS-MS) was used to investigate common isomeric glycerophosphocholine (PC) and diacylglycerol (DG) lipid species from human plasma. The LC dimension was effective for the separation of isomeric lipid species presenting distinct double bond locations or geometries but was not able to differentiate lipid isomers with distinct acyl chain positions. High resolution TIMS-MS resulted in the identification of lipid isomers that differ in the double bond locations/geometries as well as in the position of the acyl chain with resolving power (R) up to ∼410 (R ∼ 320 needed on average). Extremely small structural differences exhibiting collision cross sections (CCS) of less than 1% (down to 0.2%) are sufficient for the discrimination of the isomeric lipid species using TIMS-MS. The same level of performance was maintained in the complex biological mixture for the biologically relevant PC 16:0/18:1 lipid isomers. These results suggest several advantages of using complementary LC-TIMS-MS separations for regular lipidomic analysis, with the main emphasis in the elucidation of isomer-specific lipid biological activities.
Comprehensive characterization of proteomes comprising the same proteins with distinct post-translational modifications (PTMs) is a staggering challenge. Many such proteoforms are isomers (localization variants) that require separation followed by top-down or middle-down mass spectrometric analyses, but condensed-phase separations are ineffective in those size ranges. The variants for "middle-down" peptides were resolved by differential ion mobility spectrometry (FAIMS), relying on the mobility increment at high electric fields, but not previously by linear IMS on the basis of absolute mobility. We now use complete histone tails with diverse PTMs on alternative sites to demonstrate that high-resolution linear IMS, here trapped IMS (TIMS), broadly resolves the variants of ∼50 residues in full or into binary mixtures quantifiable by tandem MS, largely thanks to orthogonal separations across charge states. Separations using traveling-wave (TWIMS) and/or involving various time scales and electrospray ionization source conditions are similar (with lower resolution for TWIMS), showing the transferability of results across linear IMS instruments. The linear IMS and FAIMS dimensions are substantially orthogonal, suggesting FAIMS/IMS/MS as a powerful platform for proteoform analyses.
The structural elucidation of native macromolecular assemblies has been a subject of considerable interest in native mass spectrometry (MS), and more recently in tandem with ion mobility spectrometry (IMS-MS), for a better understanding of their biochemical and biophysical functions. In the present work, we describe a new generation trapped ion mobility spectrometer (TIMS), with extended mobility range (K 0 = 0.185−1.84 cm 2 •V −1 •s −1 ), capable of trapping high-molecular-weight (MW) macromolecular assemblies. This compact 4 cm long TIMS analyzer utilizes a convex electrode, quadrupolar geometry with increased pseudopotential penetration in the radial dimension, extending the mobility trapping to high-MW species under native state (i.e., lower charge states). The TIMS capabilities to perform variable scan rate (Sr) mobility measurements over short time (100−500 ms), high-mobility resolution, and ion-neutral collision cross-section (CCS N 2 ) measurements are presented. The trapping capabilities of the convex electrode TIMS geometry and ease of operation over a wide gas flow, rf range, and electric field trapping range are illustrated for the first time using a comprehensive list of standards varying from CsI clusters (n = 6−73), Tuning Mix oligomers (n = 1−5), common proteins (e.g., ubiquitin, cytochrome C, lysozyme, concanavalin (n = 1−4), carbonic anhydrase, β clamp (n = 1−4), topoisomerase IB, bovine serum albumin (n = 1−3), topoisomerase IA, alcohol dehydrogenase), IgG antibody (e.g., avastin), protein−DNA complexes, and macromolecular assemblies (e.g., GroEL and RNA polymerase (n = 1−2)) covering a wide mass (up to m/z 19 000) and CCS range (up to 22 000 Å 2 with <0.6% relative standard deviation (RSD)).
Ion mobility mass spectrometry data were collected on a set of five class II lasso peptides and their branched-cyclic topoisomers prepared in denaturing solvent conditions with and without sulfolane as a supercharging agent. Sulfolane was shown not to affect ion mobility results and to allow the formation of highly charged multiply protonated molecules. Drift time values of low charged multiply protonated molecules were found to be similar for the two peptide topologies, indicating the branched-cyclic peptide to be folded in the gas phase into a conformation as compact as the lasso peptide. Conversely, high charge states enabled a discrimination between lasso and branched-cyclic topoisomers, as the former remained compact in the gas phase while the branched-cyclic topoisomer unfolded. Comparison of the ion mobility mass spectrometry data of the lasso and branched-cyclic peptides for all charge states, including the higher charge states obtained with sulfolane, yielded three trends that allowed differentiation of the lasso form from the branched-cyclic topology: low intensity of highly charged protonated molecules, even with the supercharging agent, low change in collision cross sections with increasing charge state of all multiply protonated molecules, and narrow ion mobility peak widths associated with the coexistence of fewer conformations and possible conformational changes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.