This study demonstrates the feasibility of utilizing the 3D 4K-HD EX system and highlights potential technical assets of this novel technology in regard to optics, ergonomics, and maneuverability. Further clinical research is needed to examine the clinical effectiveness of the EX system for different surgical approaches through quantitative methodology.
Age, sex, body mass index, and the presence and extent of calcified atherosclerosis in both the abdominal aorta and iliac arteries are significantly associated with increasing aortic diameter independent of the other cardiovascular disease risk factors.
BACKGROUND
Cerebral bypass operation is a technically challenging operation that requires excellent surgical visibility and efficient ergonomics to minimize complications and maximize successful revascularization. Despite the operative microscope's utilization for the past two generations, there remains a need for continued improvement in operative visualization and surgical ergonomics.
OBJECTIVE
To report the positives and negatives of our initial experience using a novel 4 K high-definition (4K-HD) 3-dimensional (3D) exoscope (EX) for cranial bypass surgery.
METHODS
A retrospective review over 6 mo was performed of all patients who have undergone cerebral bypass surgery at a single institution using the 4K-HD 3D EX. Advantages and disadvantages of the EX and clinical outcome of the patients were assessed.
RESULTS
A total of 5 patients underwent cerebral EC-IC bypass surgery with no EX-related complications and successful revascularization. The lightweight design of the EX allowed for easy instrument maneuverability as well as uncomplicated surgical set up in the operating room. The assistance of the cosurgeon was significantly more efficient compared to that of the operating microscope. The large monitor allowed for an immersive, collaborative, and valuable educational surgical experience.
CONCLUSION
Using the EX for cerebral bypass surgery, with 3D ultra-high-definition optics, enhancements of ergonomics, and improved training, we believe that the 3D 4K-HD EX may represent the next generation of operative scopes in microneurosurgery.
Background: Thirty minutes has been considered as the threshold for tolerable warm ischemic time (WIT). Recent reports demonstrate recovery of renal function after longer WIT. We assessed renal histology according to different WIT in a 2-kidney porcine model. Methods: Twelve female pigs were randomized to an open or laparoscopic group. Each pig was further randomized within each group to clamping the left renal artery for 5, 15, 30, 45, 60 or 180 minutes. Preclamping left renal biopsies were performed on each pig. The contralateral kidney in each animal was used as an individual control. On postoperative day 14, all animals underwent bilateral nephrectomies. Preclamping left renal biopsies and all renal specimens were evaluated by a blinded veterinary pathologist. Results: One pig died in the open group after 180 minutes of clamping. Histopathology did not show any significant changes between the two groups and across clamp times from 5 to 60 minutes. After 180 minutes of laparoscopic clamping, there was evidence of diffuse necrosis. Interpretation: Sixty minutes of ischemia did not show any permanent renal damage in both groups. Further studies are needed to verify these findings in humans. A prolonged ischemic time without permanent renal damage would be helpful in partial nephrectomy. Warm ischemic time of 180 minutes exceeded the renal ischemic burden based on histological features.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.