Insecure networks are vulnerable to cyber-attacks, which may result in catastrophic damages on the local and global scope. Nevertheless, one of the tedious tasks in detecting any type of attack in a network, including DoS attacks, is to determine the thresholds required to discover whether an attack is occurring or not. In this paper, a hybrid system that incorporates different heuristic techniques along with a Finite State Machine is proposed to detect and classify DoS attacks. In the proposed system, a Genetic Programming technique combined with a Genetic Algorithm are designed and implemented to represent the system core that evolves an optimized tree-based detection model. A Hill-Climbing technique is also employed to enhance the system by providing a reference point value for evaluating the optimized model and gaining better performance. Several experiments with different configurations are conducted to test the system performance using a synthetic dataset that mimics real-world network traffic with different features and scenarios. The developed system is compared to many state-of-art techniques with respect to several performance metrics. Additionally, a Mann-Whitney Wilcoxon test is conducted to validate the accuracy of the proposed system. The results show that the developed system succeeds in achieving higher overall performance and prove to be statistically significant.
Summary Instrument equipment shelters (IESs) are important control buildings within operating plants, housing the critical instrumentation and control system (ICS) panels that are essential for plant operations. At one such IES building in one of the plants operated by Abu Dhabi Gas Industries Limited (GASCO), frequent tripping of ICS panels was encountered, without pre-alarm indication, leading to plant upsets and posing risk to the safe operations of the plant. Occasionally, the odor of hydrogen sulfide (H2S) was observed. This paper addresses the measures undertaken to identify the source of generation and diffusion of corrosive agents into the IES and remedial measures to eliminate this chronic problem. A detailed study was carried out that included soil- and water-sample collection and specialized laboratory testing, collection and testing of electronic cards, discussion with control-system vendors, and desktop evaluation of data. Analysis of electronic cards identified corrosion of electronic components within the panels as the primary reason for the tripping of panels. Corrosion of electronic components was concluded to be caused mainly by diffusion of H2S into the building, also as confirmed by control-system vendors. Ingress of corrosive agents through air inlets/doors was eliminated as a cause because of the absence of any signs of corrosion in heating, ventilation, and air-conditioning (HVAC) air intakes and because of maintenance of positive air pressure within the building. Extensive investigation and testing of soil indicated the presence of a high concentration of sulfate-reducing bacteria (SRB) in the vicinity of the building. A high groundwater table containing sulfates provided nutrition to the SRB. The bacteria reduced the sulfates present in the groundwater to H2S. The H2S, thus generated, diffused into the building through cable entry sleeves, reaching the area beneath the false flooring on which panels were mounted, and subsequently entering the panels. The presence of conducive temperature and humidity facilitated the reaction of H2S with electronic cards, thereby causing corrosion and tripping of panels. The key remedial measures that were recommended—namely, dewatering the surrounding area and lowering groundwater levels to starve the bacteria, thus rendering it dormant and preventing H2S generation, and sealing of cable entry sleeves to prevent any external gas ingress into the building—were implemented, resulting in resolution of the issue and maintaining the safety and integrity of plant operations. Tripping of ICS panels because of H2S generation by bacteria present in soil is a rare phenomenon, not commonly encountered in oil and gas plants. In areas where the groundwater table is high, the construction of buildings needs to be planned carefully. Geotechnical investigation shall include testing for the presence of organic content, sulfates, and SRB in soil and groundwater, in addition to conventional tests.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.