Cutaneous melanoma is a severe and life-threatening form of skin cancer with growing incidences. While novel interventions have improved prognoses for these patients, early diagnosis of targeted treatment remains the most effective approach. MicroRNAs have grown to good use as potential biomarkers for early detection and as targets for treatment. miR-155 is well-studied for its role in tumor cell survival and proliferation in various tissues, although its role in melanoma remains controversial. In silico data analysis was performed in the dbDEMC v.3 to identify differentially expressed miRNA. We validated gene targets in melanoma using TarBase v8.0 and miRPath v3.0 and determined protein-protein interactions of the target genes. One hundred forty patients (age range 21–90 years) with cutaneous melanoma who underwent resection were included. Molecular assessment using Real-Time RT-qPCR, clinicopathological associations, and a literature review for the different roles of miR-155 in melanoma were performed. Analysis of the dbDEMC reveals controversial findings. While there is evidence of upregulation of miR-155 in primary and metastatic melanoma samples, others suggest decreased expression in later-stage melanoma and cases with brain metastasis. miR-155 has been overexpressed in prior cases of melanoma and precancerous lesions, and it was found to be dysregulated when compared to benign nevi. While miR-155 expression was associated with favorable outcomes in some studies, others showed an association with metastasis. Patients with high levels of miR-155 also noted reduction after receiving anti-PD-1 treatment, correlated with more prolonged overall survival. In our patient’s cohort, 22.9% relapsed during treatment, and 45% developed recurrence, associated with factors such as lymph node infiltration, high mitotic index, and positive staining for CD117. Although overall analysis revealed miR-155 downregulation in melanoma specimens compared to non-cancer tissues, increased expression of miR-155 was associated with cases of superficial spreading melanoma subtype (p = 0.005) and any melanoma with a high mitotic rate (p = 0.010). The analysis did not identify optimum cutoff values to predict relapse, recurrence, or mortality. In conclusion, miR-155 could have, in part, a potential prognostic utility in cutaneous melanoma. Further mechanistic studies are required to unravel the multifunctional role of miR-155 in melanoma.
Background and objectiveThe use of radiation imaging techniques in operation theaters is essential for numerous surgical procedures and patients' overall well-being. Radiation imaging techniques enable the surgeon to have a real-time visualization of the anatomy and to perform operations with a greater chance of success, decrease rates of patient morbidity, and enable surgeons to obtain imaging records before the patient leaves the theater room. However, with the increased use of imaging techniques in orthopedic surgical operations, orthopedic surgeons are being exposed to higher levels of radiation, and hence they can be classified as a high-risk group for occupational radiation exposure. This study aimed to assess orthopedic surgeons' awareness and knowledge regarding radiation exposure safety. Materials and methodsA questionnaire-based descriptive cross-sectional study was conducted from January to March 2022 to assess the knowledge regarding ionizing radiation exposure safety among orthopedic surgeons, including consultants, specialists, and residents, at both private and governmental hospitals in Al-Madinah city, Saudi Arabia. Ethical approval was obtained from the Ministry of Health (MOH) of Al-Madinah (approval number: H-03-l.l-084). The applied statistical tests were frequency and MCT tests for univariate variables while Chisquare was applied for bivariate variables. With a 95% confidence interval (CI), a p-value of more than 0.05 was used as the cut-off value for the significance level. ResultsA total of 57 surgeons participated in the study, of which 57.9% were exposed to radiation two to three times per week. Additionally, more than half of the physicians (66.7%) were not trained to use fluoroscopy (C-arm machine). Of note, 78.9% of orthopedic surgeons reported that they used the protective apron as protective equipment, while 17.5% of them used both a protective apron and thyroid shield. However, only less than half of the orthopedic surgeons (43.9%) in our study practiced radiation safety in the operating room. ConclusionOur study revealed a lack of knowledge and awareness related to ionizing radiation exposure safety among orthopedic surgeons in Al-Madinah city, Saudi Arabia.
This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.