Objectives To investigate whether the use of adjuncts such as stylet, railroaded bougie, and preloaded bougie increases first‐pass success rate and decreases time to successful intubation when intubating simulated infant airways using direct laryngoscopy. Methods A crossover study using experienced practitioners (who were required to carry out emergency pediatric intubations as part of their usual practice) was completed. Participants completed a random sequence of 4 intubations in simulated “easy” airways and 4 intubations in simulated “difficult” airways, using naked endotracheal tube, stylet, railroaded bougie, and preloaded bougie on standardized infant airway manikins. First‐pass success rates and times to successful intubations were measured. Results From June 1 to December 30, 2019, 109 participants performed a total of 872 intubation attempts. In the easy airway, both naked endotracheal tube (mean 96.3% [95% confidence interval 90.9%–99.0%]) and stylet (mean 98.2% [95% confidence interval 93.5%–99.8%]) had higher first‐pass success rates than railroaded bougie and preloaded bougie. In the difficult airway, stylet (mean 76.1% [95% confidence interval 67.0%–83.8%]) had the highest first‐pass success rate, followed by the naked endotracheal tube, and then both the railroaded bougie and preloaded bougie. Differences in first‐pass success rates were independent of the participants’ numbers of previous pediatric intubations. Conclusion Results of this simulation‐based study suggest that stylet should be used as the first attempt technique for infant intubations regardless of the presence or absence of predicted airway difficulty. This finding needs further validation using alternative models and in non‐simulation settings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.